domain of a Read Tracks operation, the ‘next’ track is the track that is next in
sequence.
If the data area length is zero, the control unit neither sends the data area nor
reports an exception status. The read operation continues with the next count
area, if any, on the track.
Ending Status:
The control unit presents channel end and device end status
when data transfer completes. When the command completes, the control unit is
oriented to the data area of the last record on the track.
Chapter 4. Command Descriptions
4-73