
The byte descriptions follow:
Byte 1, Logical Volume Address.:
The address the channel program is using.
Byte 2, Number of Logical Volumes with Statistics:
The number of logical
volumes in the subsystem accessible from the channel minus one. The value of
byte 2 ranges from x'00' to x'FF' to describe 1 to 256 logical volumes.
Byte 3, Number of Statistic Sets per Logical Volume:
The number of statistics
sets provided per addressable logical volume.
Byte 6 –7, Size of Statistics Record per Logical Volume:
The number of bytes
in each statistics set. Internal Disk sends 192 bytes in each statistics set.
Byte 10 – 13, Installed Cache Capacity in Bytes:
The number of bytes that
have been configured for the Internal Disk Subsystem cache.
Table
4-38. Sense Subsystem Status Return Data
Bytes
Value
Description
0
x'00'
Format zero is the only format supported by
Internal Disk
1
x'aa'
Logical Volume Address
2
x'nn'
Number of Logical Volumes with Statistics
3
x'01'
Number of Statistics Sets per Logical Volume
4
x'00'
Overall caching status, set to zeros
5
x'00'
Overall nonvolatile storage status, set to zeros
6–7
x'00C0'
Size of Statistics Record per Logical Volume (192
Bytes)
8–9
x'0000'
Reserved, set to zero
10–13
x'n...n'
Installed Cache Capacity in Bytes
14–17
x'n...n'
Available Cache Capacity in Bytes
18–21
x'0...0'
Pinned Cache Space, set to zeros
22–25
x'0...0'
Offline Cache Space, set to zeros
26
x'fw'
Internal Disk RAID Fast Write Status
27
x'00'
Device Status, set to zeros
28–31
x'b...b'
Configured Non-Volatile Storage Capacity at the
RAID adapter in bytes
32–35
x'0...0'
Pinned Non-Volatile Storage Capacity, set to zeros
36
x'ds'
Device Status - Group 2. Bits 0-4 and bits 6-7 are
not used by Internal Disk. Set to zeros. Bit 5, set to
b'1' when logical volume is part of a RAID Array
that is undergoing RAID rebuild.
37
x'00'
Reserved, set to zeros
38–39
x'ssss'
Subsystem ID (SSID)
40–43
x'0...0'
Storage Status, set to zeros
Chapter 4. Command Descriptions
4-137
Содержание Multiprise 3000
Страница 1: ...S 390 Multiprise 3000 Enterprise Server R IBM Internal Disk Subsystem Reference Guide SA22 1025 00 ...
Страница 2: ......
Страница 3: ...S 390 IBM Internal Disk Subsystem Reference Guide SA22 1025 00 ...
Страница 32: ...2 12 Internal Disk Subsystem Reference Guide ...
Страница 38: ...3 6 Internal Disk Subsystem Reference Guide ...
Страница 182: ...4 144 Internal Disk Subsystem Reference Guide ...
Страница 198: ...5 16 Internal Disk Subsystem Reference Guide ...
Страница 214: ...6 16 Internal Disk Subsystem Reference Guide ...
Страница 234: ...A 10 Internal Disk Subsystem Reference Guide ...
Страница 238: ...B 4 Internal Disk Subsystem Reference Guide ...
Страница 243: ...4 lease the Code or any copy of it Appendix C Warranties C 5 ...
Страница 244: ...C 6 Internal Disk Subsystem Reference Guide ...
Страница 248: ...D 4 Internal Disk Subsystem Reference Guide ...
Страница 254: ...X 6 Internal Disk Subsystem Reference Guide ...
Страница 263: ......
Страница 264: ...IBM Printed in the United States of America on recycled paper containing 10 recovered post consumer fiber SA22 1 25 ...