451
Appendix
Axis-Specific Parameters
No.
Parameter name
Default value
(Reference)
Input range
Unit
Remarks
34 Brake equipment
specification
0,
0,
1,
1,
0,
0
0 or 1
0: Not equipped, 1: Equipped
35 Brake unlock check time
150
0 ~ 3000
msec
Time after receiving a brake-unlock start response
until transition to an operation-enabled status
36 Brake lock check time
300
0 ~ 1000
msec
Time after receiving a brake-lock start response
until start of servo OFF
37 For future extension
(Change prohibited)
0
0 or 1
Reference only
for SCARA axes
(axes 1 to 4)
38 Encoder
absolute/incremental type
1,
1,
1,
1,
0,
0
0 or 1
Reference only
for SCARA axes
(axes 1 to 4)
0: INC, 1: ABS
(Change is prohibited for SCARA axes (axes 1 to
4))
39 For future extension
(Change prohibited)
0
0H ~ FFFFFFFFH
40 For future extension
(Change prohibited)
0
0H ~ FFFFFFFFH
41 For future extension
(Change prohibited)
0
0H ~ FFFFFFFFH
42 Encoder resolution
131072
0 ~ 99999999
Reference only
for SCARA axes
(axes 1 to 4)
Pulse/rev,
0.001
m
Pulse
Pulses (before division)/rev, in the case of a rotary
encoder
43 Encoder division ratio
2,
2,
2,
2,
3,
3
-7 ~ 7
Reference only
for SCARA axes
(axes 1 to 4)
Pulses are multiplied by (“n”th power of 1/2).
44 Length measurement
correction
0
-99999999 ~
99999999
0.001
mm/1M
Valid only for linear movement axes. (Coordinates
other than the encoder reference Z point will
change proportionally.)
(Used for SCARA axis 3 (Zc) and linear
movement axes (axes 5 and 6 (6-axis type)))
45~
46
(For extension)
0
47 Screw lead
20000
1 ~ 99999999
Reference only
for SCARA axes
(axes 1 to 4)
0.001 mm Valid only for linear movement axes.
(Used for SCARA axis 3 (Zc) and linear
movement axes (axes 5 and 6 (6-axis type)))
48~
49
(For extension)
0
50 Gear ratio numerator
1,
1,
11,
1,
1,
1
1 ~ 99999999
Reference only
for SCARA axes
(axes 1 to 4)
452
Appendix
Axis-Specific Parameters
No.
Parameter name
Default value
(Reference)
Input range
Unit
Remarks
51 Gear ratio numerator
50,
50,
10,
15,
1,
1
1 ~ 99999999
Reference only
for SCARA axes
(axes 1 to 4)
52 (For extension)
0
53 Setting bit pattern 1 of
each axis
0
0H ~
FFFFFFFFH
Bits 0 to 3: For future extension
54 Travel distance for push-
motion stop detection at
movement to absolute
reset position/home return
20
1 ~ 99999
0.001 mm Used for confirmation of push motion operation at
movement to absolute reset position/home return.
(Used for SCARA axis 3 (Zc) and linear
movement axes (axes 5 and 6 (6-axis type)))
55 Travel distance for push-
motion stop detection at
positioning
30
1 ~ 99999
0.001 mm Used for confirmation of push motion operation
effected by a PUSH command.
(Used for SCARA axis 3 (Zc) and linear
movement axes (axes 5 and 6 (6-axis type)))
56 Deviation ratio for forced
push-motion completion at
movement to absolute
reset position/home return
5000
1 ~ 99999
Deviation is compared against “Steady-state
deviation of push speed + Push-speed pulse
speed x Abort deviation ratio.” (Used only for axis
3 (Zc))
57 Push-abort deviation ratio
at positioning
3000
1 ~ 99999
Deviation is compared against “Steady-state
deviation of push speed + Push-speed pulse
speed x Abort deviation ratio.”
58 Positioning band
50,
50,
100,
150,
100,
100
1 ~ 9999
0.001 mm,
0.001 deg
59 Allowable deviation error
ratio
(Maximum speed pulse
ratio)
85
Reference only
For adjustment by the manufacturer
60 PPG (Position gain)
60,
60,
60,
60,
30,
30
1 ~ 9999
* Change is prohibited for SCARA axes (axes 1 to
4) unless instructed by the manufacturer.
61 PFAG
0
0 ~ 999
* Change is prohibited for SCARA axes (axes 1 to
4) unless instructed by the manufacturer.
62 Linear movement axis
synchro FB gain
0,
0,
0,
0,
77,
77
1 ~ 1000
Reference only
for SCARA axes
(axes 1 to 4)
* Valid for linear movement axes (axes 5 and 6 (6-
axis type)) only.
(Main application version 0.12 or later)
63 Stop special output range
1
0 ~ 9999
Pulse
Invalid if “0” is set.
64 Stop special output value
1
0 ~ 999
DRVVR
65 Mating synchro-axis
number (linear movement
axis)
0
0 ~ 8
Reference only
for SCARA axes
(axes 1 to 4)
Must be input for both axes. (Of the axis pair, the
axis with the smaller axis number becomes the
master axis. Both axes must have the same
resolution characteristics. Commands cannot be
issued to the slave axis.) (Invalid if “0” is set)
* Valid for linear movement axes (axes 5 and 6
(6-axis type)) only.
(Main application version 0.15 or later)
66 Mode selection for
rotational movement axis
(linear movement axis)
0
0 ~ 5
Reference only
for SCARA axes
(axes 1 to 4)
0: Normal, 1: Index mode
* Valid for linear movement axes (axes 5 and 6
(6-axis type)) only.
(Main application version 0.12 or later)
454
Содержание X-SEL PX
Страница 1: ...Operation ManualSeventh Edition X SEL Controller PX QX Type Tenth Edition ...
Страница 2: ......
Страница 8: ......
Страница 14: ......
Страница 39: ...15 Part 1 Installation Reference Circuit Diagram Surge absorber Solenoid valve Controller 0 V 15 ...
Страница 410: ...383 Appendix 386 ...
Страница 452: ...425 Appendix 5 428 ...
Страница 559: ......