191
Part 4 Commands
GDCL (Get deceleration data)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional Optional GDCL Variable
number
Position
number
CP
[Function] Obtain deceleration data from the deceleration item in the position data specified in
operand 2, and set the value in the variable specified in operand 1.
[Example]
GDCL
100
10
Set the deceleration data at position No. 10 in variable
100.
If the position data is set as above when the command is executed, 0.8 will be set in variable 100.
192
Part 4 Commands
1.11 Actuator Control Declaration
VEL (Set speed)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional
Optional
VEL Speed Prohibited
CP
[Function] Set the travel speed for CP operation in the value specified in operand 1.
The unit is mm/sec.
(Note 1)
Decimal places cannot be used.
(Note 2)
The minimum speed is 1 mm/s.
[Example 1]
VEL
100
Set the speed to 100 mm/sec.
MOVL
1
Move to point 1 at 100 mm/sec.
[Example 2]
VEL
500
Set the speed to 500 mm/sec.
MOVL
2
Move to point 2 at 500 mm/sec.
194
Содержание X-SEL PX
Страница 1: ...Operation ManualSeventh Edition X SEL Controller PX QX Type Tenth Edition ...
Страница 2: ......
Страница 8: ......
Страница 14: ......
Страница 39: ...15 Part 1 Installation Reference Circuit Diagram Surge absorber Solenoid valve Controller 0 V 15 ...
Страница 410: ...383 Appendix 386 ...
Страница 452: ...425 Appendix 5 428 ...
Страница 559: ......