183
Part 4 Commands
PTST (Check position data)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional Optional PTST Axis
pattern
Position
number
CC
[Function] Check if valid data is contained in the axis pattern specified in operand 1 at the position
number specified in operand 2.
The output will turn ON if none of the data specified by the axis pattern is available (=
position data display on the teaching pendant: X.XXX / position data display in the PC
software: blank). 0 is treated as valid data.
[Example 1]
PTST 11
10
300
Turn ON output 300 if there are no valid values of the
X and Y-axes at position 10.
Output 300 will turn OFF if the position data is given
as follows:
[Example 2]
An axis pattern can be indirectly specified using a variable. An example of specifying the
operation in [Example 1] indirectly using a variable is shown below.
11 (binary)
3 (decimal)
LET
1
3
Assign 3 to variable 1.
PTST *1
10
300
[Example 3]
LET
1
11
Assign 11 to variable 1.
PTST 1011 *1
600
Turn ON flag 600 if there are no valid values in the
data of the X, Y and R-axes at the content of variable
1 (position 11).
Flag 600 will turn ON if the position data is given as
follows:
184
Part 4 Commands
PVEL (Assign speed data)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional Optional PVEL Speed Position
number
CP
[Function] Write the SCARA CP operation speed/linear movement axis speed specified in operand 1,
to the position number specified in operand 2. The unit of operand 1 is mm/sec.
(Note)
If a negative value is written with a PVEL command, an alarm will generate when that
position is specified in a movement operation, etc. Exercise caution.
[Example 1]
PVEL
100
10
Write speed 100 mm/s to position No. 10.
[Example 2]
LET
1
100
Assign 100 to variable 1.
LET
2
10
Assign 10 to variable 2.
PVEL
*1
*2
Write the content of variable 1 (speed 100 mm/s) to the
content of variable 2 (position 10).
186
Содержание X-SEL PX
Страница 1: ...Operation ManualSeventh Edition X SEL Controller PX QX Type Tenth Edition ...
Страница 2: ......
Страница 8: ......
Страница 14: ......
Страница 39: ...15 Part 1 Installation Reference Circuit Diagram Surge absorber Solenoid valve Controller 0 V 15 ...
Страница 410: ...383 Appendix 386 ...
Страница 452: ...425 Appendix 5 428 ...
Страница 559: ......