435
Appendix
I/O Parameters
No.
Parameter name
Default value
(Reference)
Input range
Unit
Remarks
100 Used by the SIO system
(SP3) (extended)
28100010H
0H ~
FFFFFFFFH
Bits 28 to 31: Baud rate type (0: 9.6, 1: 19.2, 2: 38.4,
3: 57.6, 4: 76.8, 5: 115.2 kbps)
Bits 24 to 27: Data length (7 or 8)
Bits 20 to 23: Stop bit length (1 or 2)
Bits 16 to 19: Parity type (0: None, 1: Odd, 2: Even)
Bits 12 to 15: Communication mode (0: RS232C, 1:
RS422, 2: RS485) * Only “0” can be
selected for board channels other than
Nos. 1 and 2
Bits 8 to 11:
Receive operation type (0: RS485 =
Forcibly enable receive immediately
after send, RS232C/RS422 = Forcibly
enable receive immediately before
send
1: Do not forcibly enable receive at
send)
Bits 4 to 7:
Board channel assignment number (1:
D-sub upper, 2: D-sub lower, 3: Flat
connector upper, 4: Flat connector
lower)
Bits 0 to 3:
Expanded I/O slot assignment number
(Expanded I/O slots 1 to 3 from the slot
next to the standard IO (I/O1) slot. * “0”
means no slots are used)
101 (For SIO system (SP3)
extension (extension))
0
0H ~
FFFFFFFFH
102 Used by the SIO system
(SP4) (extended)
28100020H
0H ~
FFFFFFFFH
(Same as with I/O parameter No. 100)
103 (For SIO system (SP4)
extension (extension))
0
0H ~
FFFFFFFFH
104 Used by the SIO system
(SP5) (extended)
28100010H
0H ~
FFFFFFFFH
(Same as with I/O parameter No. 100)
105 (For SIO system (SP5)
extension (extension))
0
0H ~
FFFFFFFFH
106 Used by the SIO system
(SP6) (extended)
28100020H
0H ~
FFFFFFFFH
(Same as with I/O parameter No. 100)
107 (For SIO system (SP6)
extension (extension))
0
0H ~
FFFFFFFFH
108 Used by the SIO system
(SP7) (extended)
28100010H
0H ~
FFFFFFFFH
(Same as with I/O parameter No. 100)
109 (For SIO system (SP7)
extension (extension))
0
0H ~
FFFFFFFFH
110 Used by the SIO system
(SP8) (extended)
28100020H
0H ~
FFFFFFFFH
(Same as with I/O parameter No. 100)
111 (For SIO system (SP8)
extension (extension))
0
0H ~
FFFFFFFFH
112 Used by the SIO system
(SP9) (extended)
28100030H
0H ~
FFFFFFFFH
(Same as with I/O parameter No. 100)
113 (For SIO system (SP9)
extension (extension))
0
0H ~
FFFFFFFFH
114 Used by the SIO system
(SP10) (extended)
28100040H
0H ~
FFFFFFFFH
(Same as with I/O parameter No. 100)
115 (For SIO system (SP10)
extension (extension))
0
0H ~
FFFFFFFFH
116~
119
(For extension)
0
120 Network attribute 1
1H
0H ~
FFFFFFFFH
Bits 0 to 3: CC-Link remote register area
H/L byte swap selection (0: Do not
swap, 1: Swap)
* The number of used ports and
number of occupied stations in I/O
parameter Nos. 14 and 15 must
match.
121 Network attribute 2
0
0H ~
FFFFFFFFH
122 Network attribute 3
0
0H ~
FFFFFFFFH
436
Appendix
I/O Parameters
No.
Parameter name
Default value
(Reference)
Input range
Unit
Remarks
123 Network attribute 4
0H
0H ~
FFFFFFFFH
Bits 0 to 3: Ethernet TCP/IP message
communication
IP address of connection destination on
server
Whether to permit 0.0.0.0 (IP address
of connection destination can be
ignored)
(0: Do not permit
1: Permit (not recommended))
* Note: Number of clients that can be
connected simultaneously to one
server port channel = 1
124 Network attribute 5
0H
0H ~
FFFFFFFFH
Ethernet TCP/IP message communication attribute
Ethernet client/server type
(0: Not in use
(
1: Client (Automatic assignment of own port
number)
(2: Client (Specification of own port number)
This setting is not recommended because
of device limitations, such as an error
generation when the port is opened for
approx. 10 minutes after disablement of
close response check due to a power
failure at the connection destination, etc.)
3: Server (Specification of own port number))
* Note: Number of clients that can be connected
simultaneously to one server port channel = 1
Bits 0 to 3:
IAI protocol B/TCP (MANU mode)
* PC software can be connected only in the
case of a client.
Bits 4 to 7:
IAI protocol B/TCP (AUTO mode)
* PC software can be connected only in the
case of a client.
Bits 8 to 11: Channel 31 opened to user
Bits 12 to 15: Channel 32 opened to user
Bits 16 to 19: Channel 33 opened to user
Bits 20 to 23: Channel 34 opened to user
* If the parameter settings for own port number,
client/server type, IP address of connection
destination and port number of connection
destination do not match completely in the IAI
protocol B/TCP MANU or AUTO mode, the
connection will be cut off when the MANU/AUTO
mode is switched.
125 Network attribute 6
31E32H
0H ~
FFFFFFFFH
Bits 0 to 7:
Module-initialization check timer
setting when Ethernet is used (100
msec)
Bits 8 to 15: Module-initialization check timer
setting when Ethernet is not used
(100 msec)
Bits 16 to 23: Increment of "PC/TP reconnection
delay time upon software reset"
when Ethernet is used (sec)
PC: PC software
TP: Teaching pendant
438
Содержание X-SEL PX
Страница 1: ...Operation ManualSeventh Edition X SEL Controller PX QX Type Tenth Edition ...
Страница 2: ......
Страница 8: ......
Страница 14: ......
Страница 39: ...15 Part 1 Installation Reference Circuit Diagram Surge absorber Solenoid valve Controller 0 V 15 ...
Страница 410: ...383 Appendix 386 ...
Страница 452: ...425 Appendix 5 428 ...
Страница 559: ......