427
Appendix
1. I/O Parameters
No.
Parameter name
Default value
(Reference) Input range
Unit
Remarks
1 I/O port assignment type
1
0 ~ 20
0: Fixed assignment
1: Automatic assignment (Priority: Network I/F module >
Slot 1 (standard I/O) ~ * Ports are assigned only for
the installed adjoining slots, starting from slot 1 = For
safety reasons)
2 Input port start number
with fixed standard I/O
assignments (I/O1)
000
-1 ~ 599
0 + (Multiple of 8) (Invalid if a negative value is set)
3 Output port start number
with fixed standard I/O
assignments (I/O1)
300
-1 ~ 599
300 + (Multiple of 8) (Invalid if a negative value is set)
4 Input port start number
with fixed expanded I/O1
assignments (I/O2)
-1
-1 ~ 599
0 + (Multiple of 8) (Invalid if a negative value is set) (Slot
next to the standard I/O slot)
5 Output port start number
with fixed expanded I/O1
assignments (I/O2)
-1
-1 ~ 599
300 + (Multiple of 8) (Invalid if a negative value is set)
6 Input port start number
with fixed expanded I/O2
assignments (I/O3)
-1
-1 ~ 599
0 + (Multiple of 8) (Invalid if a negative value is set)
7 Output port start number
with fixed expanded I/O2
assignments (I/O3)
-1
-1 ~ 599
300 + (Multiple of 8) (Invalid if a negative value is set)
8 Input port start number
with fixed expanded I/O3
assignments (I/O4)
-1
-1 ~ 599
0 + (Multiple of 8) (Invalid if a negative value is set)
9 Output port start number
with fixed expanded I/O3
assignments (I/O4)
-1
-1 ~ 599
300 + (Multiple of 8) (Invalid if a negative value is set)
10 Standard I/O error monitor
(I/O1)
1
0 ~ 5
0: Do not monitor
1: Monitor
2: Monitor (Do not monitor 24-V I/O power-supply
errors)
3: Monitor (Monitor 24-V I/O power-supply errors only)
* Some exceptions apply.
* If 0 (= Do not monitor) or 2 (= Monitor (Do not monitor
24-V I/O power-supply errors)) is selected, a system
error will not generate when a 24-V I/O power-supply
error occurs. To protect the controller, however, the
actual outputs of the digital I/O board will be cut off by a
circuit later.
11 Expanded I/O1 error
monitor (I/O2)
1
0 ~ 5
0: Do not monitor
1: Monitor
2: Monitor (Do not monitor 24-V I/O power-supply
errors)
3: Monitor (Monitor 24-V I/O power-supply errors only)
* Some exceptions apply.
(Slot next to the standard I/O slot)
* If 0 (= Do not monitor) or 2 (= Monitor (Do not monitor
24-V I/O power-supply errors)) is selected, a system
error will not generate when a 24-V I/O power-supply
error occurs. To protect the controller, however, the
actual outputs of the digital I/O board will be cut off by a
circuit later.
12 Expanded I/O2 error
monitor (I/O3)
1
0 ~ 5
0: Do not monitor
1: Monitor
2: Monitor (Do not monitor 24-V I/O power-supply
errors)
3: Monitor (Monitor 24-V I/O power-supply errors only)
* Some exceptions apply..
* If 0 (= Do not monitor) or 2 (= Monitor (Do not monitor
24-V I/O power-supply errors)) is selected, a system
error will not generate when a 24-V I/O power-supply
error occurs. To protect the controller, however, the
actual outputs of the digital I/O board will be cut off by a
circuit later.
428
Appendix
No. Parameter name
Default value
(Reference)
Input range
Unit Remarks
13 Expanded I/O3 error
monitor (I/O4)
1
0 ~ 5
0: Do not monitor
1: Monitor
2: Monitor (Do not monitor 24-V I/O power-supply
errors)
3: Monitor (Monitor 24-V I/O power-supply errors only)
* Some exceptions apply.
* If 0 (= Do not monitor) or 2 (= Monitor (Do not monitor
24-V I/O power-supply errors)) is selected, a system
error will not generate when a 24-V I/O power-supply
error occurs. To protect the controller, however, the
actual outputs of the digital I/O board will be cut off by a
circuit later.
14 Number of ports using
network I/F module
remote input
0
0 ~ 256
Multiple of 8
15 Number of ports using
network I/F module
remote output
0
0 ~ 256
Multiple of 8
16 Input port start number
when network I/F
module assignments are
fixed
-1
-1 ~ 599
0 + (Multiple of 8) (Invalid if a negative value is set)
17 Output port start number
when network I/F
module assignments are
fixed
-1
-1 ~ 599
300 + (Multiple of 8) (Invalid if a negative value is set)
18 Network I/F module error
monitor
1
0 ~ 5
0: Do not monitor
1: Monitor
* Some exceptions apply.
19 (For extension)
0
20 Input filtering periods
2
1 ~ 9
msec Input signal is recognized when the status is held for
twice the period set by this parameter.
21 For future extension
(Change prohibited)
0
1 ~ 9
22 Remote-I/O-card fieldbus
ready timeout value
2000
0 ~ 99999
msec Timeout check is not performed if “0” is set.
23 Input specification for
detection of
overcurrent/abnormal
power supply for multi-
point DIO external
terminal block
0H
0H ~
FFFFFFFFH
Bits 0 to 3:
Standard I/O (I/O1) input specification
Bits 4 to 7:
Expanded I/O1 (I/O2) input specification
Bits 8 to 11: Expanded I/O2 (I/O3) input specification
Bits 12 to 15: Expanded I/O3 (I/O4) input specification
(0: Do not input error detection signal
1: Input error detection signal = IN023 in
card
2: Input error detection signal = IN047 in
card
3: Input error detection signal =
IN023/47 in card)
* Set this parameter after confirming the specification
of the multi-point DIO terminal block unit to be
connected.
* Input ports used for error detection input cannot be
used as general-purpose input ports.
430
Содержание X-SEL PX
Страница 1: ...Operation ManualSeventh Edition X SEL Controller PX QX Type Tenth Edition ...
Страница 2: ......
Страница 8: ......
Страница 14: ......
Страница 39: ...15 Part 1 Installation Reference Circuit Diagram Surge absorber Solenoid valve Controller 0 V 15 ...
Страница 410: ...383 Appendix 386 ...
Страница 452: ...425 Appendix 5 428 ...
Страница 559: ......