3. SCON-CA
93
PLC
output
SCON-CA input side (* “n” indicates the byte address of each axis.)
DO on the SCON-CA side and output data register
Position/Simplified
direct value mode 2
Half direct value
mode 2
Remote I/O mode 3
Half direct value
mode 3
PLC input
area
(bytes)
Number of occupied
bytes: 8
Number of occupied
bytes: 16
Number of occupied
bytes: 12
Number of occupied
bytes: 16
n+0, n+1
Port No.0 to 15
n+2, n+3
Target position
Target position Target
position
n+4, n+5
Specified position
number
n+6, n+7
Control signal
Positioning band
Positioning band
n+8, n+9
Speed
Speed
n+10, n+11
Acceleration/
Deceleration
Occupied area
Acceleration/
Deceleration
n+12, n+13
Pressing
current-limiting
value
Pressing
current-limiting
value
n+14, n+15
Control signal
Control signal
n+16, n+17
n+18, n+19
n+20, n+21
n+22, n+23
n+24, n+25
n+26, n+27
n+28, n+29
n+30, n+31
(Note) The Occupied area shows the domain to be occupied with the operation mode setting.
Therefore, this domain cannot be used for any other purpose. Also, exercise caution to avoid node
address duplication.