4
No.
Operation
Description
Description
5
Teaching
When the work is carried out with 2 or more persons, make it clear who is to be
the leader and who to be the follower(s) and communicate well with each other to
ensure the safety of the workers.
Perform the teaching operation from outside the safety protection fence, if
possible. In the case that the operation is to be performed unavoidably inside the
safety protection fence, prepare the “Stipulations for the Operation” and make sure
that all the workers acknowledge and understand them well.
When the operation is to be performed inside the safety protection fence, the
worker should have an emergency stop switch at hand with him so that the unit
can be stopped any time in an emergency.
When the operation is to be performed inside the safety protection fence, in
addition to the workers, arrange a watchman so that the machine can be stopped
any time in an emergency. Also, keep watch on the operation so that any third
person can not operate the switches carelessly.
Place a sign “Under Operation” at the position easy to see.
When releasing the brake on a vertically oriented actuator, exercise precaution not
to pinch your hand or damage the work parts with the actuator dropped by gravity.
* Safety protection Fence : In the case that there is no safety protection fence, the
movable range should be indicated.
6
Trial Operation
When the work is carried out with 2 or more persons, make it clear who is to be
the leader and who to be the follower(s) and communicate well with each other to
ensure the safety of the workers.
After the teaching or programming operation, perform the check operation one
step by one step and then shift to the automatic operation.
When the check operation is to be performed inside the safety protection fence,
perform the check operation using the previously specified work procedure like the
teaching operation.
Make sure to perform the programmed operation check at the safety speed.
Failure to do so may result in an accident due to unexpected motion caused by a
program error, etc.
Do not touch the terminal block or any of the various setting switches in the power
ON mode. Failure to do so may result in an electric shock or malfunction.
7 Automatic
Operation
Before the automatic operation is started up, make sure that there is nobody inside
the safety protection fence.
Before the automatic operation is started up, make sure that all the related
peripheral machines are ready for the automatic operation and there is no error
indication.
Make sure to perform the startup operation for the automatic operation, out of the
safety protection fence.
In the case that there is any abnormal heating, smoke, offensive smell, or
abnormal noise in the product, immediately stop the machine and turn OFF the
power switch. Failure to do so may result in a fire or damage to the product.
When a power failure occurs, turn OFF the power switch. Failure to do so may
cause an injury or damage to the product, due to a sudden motion of the product
in the recovery operation from the power failure.
Содержание acon
Страница 1: ...EtherNet IP IAI America Inc Operation Manual Second Edition ACON PCON SCON CA ...
Страница 2: ......
Страница 4: ......
Страница 197: ...4 Appendix 191 PLC s IP Address Controller s IP Address ...
Страница 214: ......
Страница 215: ......