2. ACON,
PCON
25
PCON
Parameter No. 25 setting
512-point mode
Electromagnetic valve mode 1
Electromagnetic valve mode 2
3 4 5
Category
Port No.
Signal name
Symbol
Signal name
Symbol
Signal name
Symbol
0
PC1
Start position 0
ST0
Start position 0
ST0
1
PC2
Start position 1
ST1
Start position 1
ST1
2
PC4
Start position 2
ST2
Start position 2
ST2
3
PC8
Start position 3
ST3
-
4
PC16
Start position 4
ST4
-
5
PC32
Start position 5
ST5
-
6
PC64
Start position 6
ST6
-
7 PC128
-
-
8
Command position
No.
PC256
Unavailable
-
Unavailable
-
9
Forced brake release BKRL
Forced brake release
BKRL
Forced brake release
BKRL
10
Operating mode
selector
RMOD
Operating mode
selector
RMOD
Operating mode
selector
RMOD
11
Home return
HOME
Home return
HOME
-
12 Pause *STP Pause *STP
-
13 Positioning
start CSTR
Unavailable
-
Unavailable
-
14 Reset RES Reset RES Reset RES
PLC output
PCON input
15
Servo ON command
SON
Servo ON command
SON
Servo ON command
SON
0
PM1
Position 0 complete
PE0
Retracting end
movement command 0
LS0
1
PM2
Position 1 complete
PE1
Retracting end
movement command 1
LS1
2
PM4
Position 2 complete
PE2
Retracting end
movement command 2
LS2
3
PM8
Position 3 complete
PE3
-
4
PM16
Position 4 complete
PE4
-
5
PM32
Position 5 complete
PE5
-
6
PM64
Position 6 complete
PE6
Unavailable
-
7
PM128
Zone 1
ZONE1
Zone 1
ZONE1
8
Completed position
No.
PM256
Position zone
PZONE
Position zone
PZONE
9
Operation mode
status
RMDS
Operation mode status
RMDS
Operation mode status
RMDS
10
Home return
completion
HEND
Home return
completion
HEND
Home return
completion
HEND
11
Positioning
completion signal
PEND
Positioning completion
signal
PEND Unavailable
-
12
Operation
preparation end
SV
Operation preparation
end
SV
Operation preparation
end
SV
13
Emergency stop
*EMGS
Emergency stop
*EMGS
Emergency stop
*EMGS
14 Alarm *ALM Alarm *ALM Alarm *ALM
PCON output
PLC input
15
Load output
judgment/
torque level
LOAD/
TRQS
Load output judgment/
torque level
LOAD/
TRQS
Unavailable -
The symbol with a * mark shows the ON signal in normal condition.
The signal described as “Unavailable” is not controlled.(ON/OFF is undefined.)