Type of connections
All the consoles available in the chassis from factory must be used.
In this type of vehicle, an additional fixation console must be mounted between the
cab and the first console installed from factory. This additional console must be lo
-
cated 100 mm from the first console installed in the factory.
Fig. 5-144 LCV_SPBGC54_012
HMC recommends using official parts supplied by HMC for additional consoles. If
original parts are not chosen, a material of at least the same quality as the original
consoles (S235JRG2) must be used, with a wall thickness of 2 mm for 5M and
3 mm for 7M.
1
First fixation console installed from factory A
100 mm
2
Additional console