Possibl
e
Cause
Judgment Criterion
Troubleshooting Method
The
time to
live
(TTL)
value
set for
the
multica
st
stream
of the
multica
st server
is very
small.
All users of the MA5612 fail to watch
all programs configured on to the
multicast server.
Increase the TTL value of multicast
packets of the multicast server.
The
upper-
layer
network
commu
nication
of the
OLT
fails.
Ping the multicast router and multicast
server from the MA5612 separately. It
is found that the MA5612 fails to ping
the multicast router and the multicast
server.
TIP
If other users of the MA5612 can watch the
program, the network between the
MA5612 and the multicast server is normal.
Troubleshoot the fault on the line
between the MA5612 and the
multicast router or the fault on the
line between the MA5612 and the
multicast server.
2.
Order a program again and then check whether the user can watch the program successfully.
l
If the user can watch the program successfully, go to
l
If the user cannot watch the program, go to
3.
Check whether all NEs are checked according to
.
l
l
If not all NEs are checked, check the remaining NEs according to
Step 5
Record the results of the preceding steps in a fault report (see Fault Report Form), fill out the
entire form, and then submit it to Huawei for technical support (see
Step 6
End.
----End
4.2.3 Pixelation in a Multicast Program
Pixelation in multicast programs is a fault that a user is online and orders a program but the
quality of the program is poor, such as pixelation. When pixelation occurs, locate the fault
according to the following procedure.
SmartAX MA5612 Multi-service Access Module
Maintenance Guide
4 Troubleshooting Services Transmitted Through a GE Port
Issue 01 (2012-07-25)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
72