Step 6
Have the MGC maintenance engineer modify the fax service data configurations on the MGC
so that they are consistent with the data plan. Then, check whether the service is restored.
l
If the service is restored, go to
l
If the service is not restored, go to
.
Step 7
Check whether the quality of the bearer network meets the requirements for the fax service.
NOTE
Users can use an associated tool to test the bearer network quality or run the
ping
command on the MA5612 to
ping the peer access gateway (AG).
In transparent transmission mode, the packet loss ratio for fax services must be less than 0.5%.
l
If the peer AG cannot be pinged or the packet loss ratio is too high, go to
l
If the peer AG cannot be pinged and there is no packet loss, go to
.
Step 8
Check whether the network connection between the MA5612 and the peer AG is normal and
whether the transmission devices are normal. If there are faults on the network or devices, rectify
the faults and ensure that the peer AG can be pinged from the MA5612 and that there is no packet
loss. Then, check whether the service is restored.
l
If the service is restored, go to
l
If the service is not restored, go to
.
Step 9
In the onhook state, perform a
8.4 POTS Subscriber Loop Line Test
l
If the test result (shown in
Conclusion
) is
Normal
, go to
.
l
If the test result (shown in
Conclusion
) is not
Normal
, the subscriber line is faulty. Connect
a fax machine to the main distribution frame (MDF) and perform a test to determine the
location of the fault. Rectify the fault as needed, for example, by replace the subscriber
line. Then, go to
Step 10
Check whether the service is restored.
l
If the service is restored, go to
l
If the service is not restored, go to
.
Step 11
Perform a test on another port on the same board to check whether the service is restored.
l
If the service is restored, go to
l
If the service is not restored, go to
.
Step 12
Replacing the service board and check whether the service is restored.
l
If the service is restored, go to
l
If the service is not restored, go to
.
Step 13
Record the results of the preceding steps in a fault report (see Fault Report Form), fill out the
entire form, and then submit it to Huawei for technical support (see
Step 14
End.
----End
4.4.2 Modem Service Failures
This section describes how to troubleshoot common modem service failures, such as when dial-
up Internet access fails or the modem goes offline repeatedly. Common modem services include
the lottery service and point of sale (POS) service.
SmartAX MA5612 Multi-service Access Module
Maintenance Guide
4 Troubleshooting Services Transmitted Through a GE Port
Issue 01 (2012-07-25)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
106