Fault Location
Location Analysis
Possible Causes
If the fault does not recur when the
user's terminal is replaced, the
fault is on the user's terminal.
The user's terminal is faulty.
Link between
user terminal and
MA5612
The link state of the user port is
offline
.
A fault has occurred on the
subscriber line.
l
The quality of the subscriber line
is deteriorated.
l
The subscriber line is old.
l
The subscriber line connectors
are loose.
The user port is deactivated.
MA5612
The fault does not recur when the
line of the affected user is
connected to another user port.
The user port is faulty.
The configured service port data is
inconsistent with the data plan.
The configured service port data,
such as the port ID, is incorrect.
If the result of the PPPoE dialup emulation test is not "success," the fault must be located on the
link between the MA5612 and the upper layer BRAS. Use the following guidelines to address
the fault more accurately.
Fault Location
Location Analysis
Possible Causes
MA5612
The configured service port data is
inconsistent with the data plan.
The configured service port data,
such as the VLAN ID, is incorrect.
The uplink port forwards no
service stream to the upper layer
device.
The uplink port on the MA5612 is
not added to the upstream VLAN.
The security configuration is
incorrect.
l
The Policy Information Transfer
Protocol (PITP) configuration is
incorrect.
l
The configured number of MAC
addresses that can be
dynamically learned by the
service port is incorrect.
l
The configuration of the anti-
MAC address spoofing function
is incorrect.
l
An access control list (ACL) that
does not allow transmission of
PPPoE packets is configured.
SmartAX MA5612 Multi-service Access Module
Maintenance Guide
5 Troubleshooting Services Transmitted Through a GPON
Port
Issue 01 (2012-07-25)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
116