l
Ensure that the jacket is in proper condition. If the jacket is convex, plucked, or damaged,
cut the improper part off the cable.
Procedure
Step 1
Use the diagonal pliers to cut the cable according to the required length.
Step 2
Put the cable through the boot for 100 mm at least. Ensure that the boot is installed in the correct
direction, as shown in
Figure A-11
Installing the boot for the RJ45 connector
Cable end where the RJ-45
connector is to be installed
100 mm
Step 3
Use a blade or a knife to peel off 20 mm of the jacket, as shown in
. Do not damage
the insulation of the wires.
Figure A-12
Peeling the jacket
Twisted pair
20 mm
Step 4
Arrange the four pair of wires properly according to the connection sequence of the network
cable.
Step 5
Ensure that the wires are 13 mm to 15 mm long. Cut off the extra length of the wires, arrange
the wires in the correct order, and then insert the wires into the RJ45 connector, as shown in
lists the wires assigned to the network cable.
SmartAX MA5612 Multi-service Access Module
Maintenance Guide
A Appendix
Issue 01 (2012-07-25)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
276