If the dialup fails, go to
.
Step 3
Check the interoperability between the user terminal and the MA5612.
1.
In ETH mode, run the
display port state portid
command on the MA5612 to check whether
Active State
of the Ethernet port is
active
.
l
If
Active State
of the Ethernet port is
active
l
If
Active State
of the Ethernet port is not
active
2.
Run the
undo shutdown portid
command to activate the Ethernet port. Then, check
whether it is in the
active
state.
l
If it is in the
active
state, go to
l
If it is not in the
active
state, go to
.
3.
Run the
display port state portid
command to check whether
Link
of the Ethernet port is
online
.
l
If
Link
of the Ethernet port is
online
, go to
.
l
If
Link
of the Ethernet port is not
online
, go to
.
4.
Perform a dialup check.
l
If the dialup is successful, go to
.
l
If the dialup fails, go to
5.
Check the quality of the physical line between the MA5612 and the user terminal to
determine whether the line is not connected properly or the line is old. Reconnect the line
properly or replace the old line as needed to ensure good line quality. Then, check whether
Link
of the Ethernet port is
online
.
l
If
Link
of the Ethernet port is
online
, go to
.
l
If
Link
of the Ethernet port is not
online
, go to
.
6.
Perform a dialup check.
l
If the dialup is successful, go to
.
l
If the dialup fails, go to
7.
In ETH mode, run the
display port state portid
command to check whether the duplex
mode, rate, network cable adaptation mode of the Ethernet port are consistent with those
of the user terminal.
l
l
If they are inconsistent, modify the parameter settings of the Ethernet port to ensure that
the parameter settings are consistent with those of the user terminal. Then, go to
.
NOTE
In ETH mode, modify the parameter settings of the Ethernet port by using the following methods:
l
Run the
auto-neg
command to enable or disable the auto-negotiation mode of the Ethernet port.
After the auto-negotiation mode of the Ethernet port is enabled, the Ethernet port automatically
negotiates the port rate and duplex mode with the interconnected port.
l
Run the
duplex
command to configure the duplex mode of the Ethernet port to full duplex or half
duplex.
l
Run the
mdi
command to configure the network cable adaptation mode of the Ethernet port.
l
Run the
speed
command to configure the rate of the Ethernet port.
8.
Perform a dialup check.
l
If the dialup is successful, go to
.
SmartAX MA5612 Multi-service Access Module
Maintenance Guide
5 Troubleshooting Services Transmitted Through a GPON
Port
Issue 01 (2012-07-25)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
118