l
If such alarms or events are generated, clear these alarms or events to rectify the fault
according to the relevant guide. Then, proceed to
l
If such alarms or events are not generated, go to
NOTE
The related alarms or events include the following:
l
0x38100005 DSP resources for voice services are insufficient
l
0x3b000002 Remote blocking
l
0x1a010001 H.248 interface interruption
l
0x13010001 Communication between the VAG and the SIP proxy server is interrupted
Step 2
Pick the phone off the hook again and check whether a dial tone is heard.
l
If a dial tone is heard, go to
.
l
If no dial tone is heard, proceed to
.
Step 3
Run the
display protocol support
command to query the current used voice protocol.
l
If the H.248 protocol is used, proceed to
.
l
If the SIP protocol is used, go to
Step 4
In the H.248 mode , run the
reset coldstart
command to reset the MG interface and make the
subscriber register again. If registration is successful, run the
display pstn state
command in
the global config mode to check whether the service management state (
CTPAdmState
) of the
POTS port is
StartSvc
.
CAUTION
In resetting the MG interface, subscriber services carried on this interface will be interrupted.
Therefore, before resetting the MG interface, ensure that no users under this interface are running
services.
l
If
CTPAdmState
is
StartSvc
, go to
.
l
If
CTPAdmState
is not
StartSvc
, proceed to
.
Step 5
In the H.248 mode, run the
display if-h248 attribute mgid
command to check whether MG
interface attributes are the same as those configured on the MGC.
l
If MG interface attributes are the same as those configured on the MGC, go to
l
If MG interface attributes are different from those configured on the MGC, run the
if-h248
attribute
command in the H.248 mode to modify MG interface attributes to be the same
as those configured on the MGC. Run the
reset coldstart
command to reset the MG
interface. Then, proceed to
.
Step 6
Pick the phone off the hook again and check whether a dial tone is heard.
l
If a dial tone is heard, go to
.
l
If no dial tone is heard, proceed to
.
Step 7
In test mode, run the
pots loop-line-test
command to perform the POTS subscriber loop line
test with the phone on the hook.
l
If the test result (shown in
Conclusion
) is
Normal
, the subscriber line and the phone are
SmartAX MA5612 Multi-service Access Module
Maintenance Guide