Step 13
In the SIP mode, run the
display if-sip attribute mgid
command to check whether SIP interface
attributes are the same as those configured on the IMS.
l
If SIP interface attributes are the same as those configured on the IMS, go to
.
l
If SIP interface attributes are different from those configured on the IMS, run the
if-sip
attribute basic
command in the SIP mode to modify SIP interface attributes to be the same
as those configured on the IMS. Run the
reset
command to reset the SIP interface. Then,
Step 14
Pick the phone off the hook again and check whether a dial tone is heard.
l
If a dial tone is heard, go to
.
l
If no dial tone is heard, proceed to
Step 15
Record the results of the preceding steps in a fault report (see Fault Report Form), fill out the
entire form, and then submit it to Huawei for technical support (see
Step 16
End.
----End
4.3.4 Continuous Dial Tone During Dialing
This section describes how to troubleshoot the fault where the dial tone does not stop when the
user begins to dial. The dial tone should stop when the user dials a number.
Location Method
Check whether the phone is
working properly
Start
Check whether the gain of a user
port is set to a very small value
Check whether the input gain of the
DSP chip is set to a very small value
Check whether any of the ports on
the same service board or adjacent
service boards are locked
End
Check whether the subscriber and
circuit lines are normal
CAUTION
To facilitate fault report, save the results of the following steps.
SmartAX MA5612 Multi-service Access Module
Maintenance Guide
4 Troubleshooting Services Transmitted Through a GE Port
Issue 01 (2012-07-25)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
88