CAUTION
To facilitate fault report, save the results of the following steps.
The parameters of the optical module in this topic comply with Class B+. Note that such
parameters are slightly different from the parameters in Class C.
Procedure
Step 1
When the queried
Run state
of the ONU is displayed as
offline
, check whether the OLT
generates the following alarms. If such alarms are generated, clear them and check whether the
fault is rectified. If the fault persists, proceed to
.
The following alarms may be generated:
l
0x2e305015 The authentication information of the ONTs conflicts
l
0x2e314021 There are illegal incursionary rogue ONTs under the port
l
0x2e314022 The ONT is rogue ONT
l
0x2e11a00b The dying-gasp of ONTi (DGi) is generated
l
0x2e11a001 The feed fiber is broken or OLT can not receive any expected optical signals
(LOS)
l
0x2e112007 The distribute fiber is broken or OLT can not receive expected optical
signals from GPON ONT(LOSi)
l
0x2e11a00a The loss of acknowledgement PLOAM message with ONTi (LOAi) occurs
Step 2
Check for the possible causes on the OLT and troubleshoot the faults accordingly. If the ONU
still fails to go online after that, proceed to
.
Possible Cause
Judgment Criterion
Troubleshooting Method
The SN configured on
the OLT is different from
the actual SN of the
ONU; hence, the ONU
fails to pass
authentication and to go
online.
Run the
display ont info
command to query the ONU
information. It is found that the
SN in the result is different
from the actual ONU SN.
Run the
ont add
command to
re-add an ONU and specify the
correct ONU SN and password.
NOTE
The ONU with a different SN is
regarded as a new one and is
founded by the OLT.
SmartAX MA5612 Multi-service Access Module
Maintenance Guide
6 System Fault Handling
Issue 01 (2012-07-25)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
203