CAUTION
To facilitate fault report, save the results of the following steps.
Procedure
Step 1
Confirm the fault scope.
l
If the fault occurs on all subscribers of the device, proceed to
l
If the fault occurs on subscribers of certain ports on the device, go to
l
If the fault occurs on subscribers using certain numbers, go to
Step 2
Run the
display pstnport electric
command to query the electrical attributes of a PSTN port.
Check whether the impedance type, current type, transmit gain, and receive gain configured on
the faulty port are the same as those configured on a normal port.
l
If the impedance type, current type, transmit gain, and receive gain configured on the faulty
port are the same as those configured on a normal port, proceed to
l
If the impedance type, current type, transmit gain, and receive gain configured on the faulty
port are different from those configured on a normal port, run the
pstnport electric set
command to configure the electrical attributes of the PSTN port again to make the electrical
attributes to be the same as those configured on a normal port. Then, proceed to
.
NOTE
When you need to configure the electrical attributes of the PSTN port in batches, you can run the
pstnport
electric batset
command.
Different countries and regions have different requirements on the electrical attributes. Therefore, the
configured electrical attributes must comply with the local standard and the interconnection parties must
have the same configurations. For example, the requirements for transmit and receive gains are as follows:
l
China: The transmit gain and receive gain of the local network are 0 dB and -3.5 dB respectively. The
transmit gain and receive gain of the toll network are 0 dB and -7 dB respectively.
l
Other countries and regions: Generally, the transmit gain the receive gain of the local network and toll
network are 0 dB and -7 dB respectively.
Step 3
Call each other again to check whether the fault is rectified.
l
If the fault is rectified, go to
l
If the fault persists, proceed to
Step 4
Run the
display mgpstnuser attribute
command to query the attributes of a PSTN subscriber,
and check whether the input and output gains of the DSP chip configured on the faulty port are
the same as those configured on a normal port.
l
If the input and output gains of the DSP chip configured on the faulty port are the same as
those configured on a normal port, go to
l
If the input and output gains of the DSP chip configured on the faulty port are different
from those configured on a normal port, run the
mgpstnuser attribute setframeid/slotid/
portiddsp-input-gaindsp-input-gain-valuedsp-output-gaindsp-output-gain-value
command to configure the attributes of the PSTN subscriber again and make the attributes
to be the same as those configured on a normal port. Then, proceed to
Step 5
Call each other again to check whether the fault is rectified.
l
If the fault is rectified, go to
SmartAX MA5612 Multi-service Access Module
Maintenance Guide
5 Troubleshooting Services Transmitted Through a GPON
Port
Issue 01 (2012-07-25)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
186