Procedure
Step 1
Run the
display board frameid/slotid
command to query the board information, and then check
whether the configured board type is the same as the one in use.
l
If the configured board type is the same as the one in use, go to
.
l
If the configured board type is different from the one in use, replace the current board with
one configured in the system. Then, go to
l
Conversely, if the configured board type is different from the one in use, run the
board
delete frameid/slotid
command to delete the board type configured in the system if the
board type configured in the system is incorrect, and then run the
board confirm frameid/
slotid
command to confirm the board once the system automatically detects the board. Then,
Step 2
Wait five minutes. Then, check whether the fault is rectified.
l
If the fault is rectified, go to
l
If the fault persists, go to
.
Step 3
Check whether the ambient temperature of the device is too high.
NOTE
A board repeatedly resets if its ambient temperature is too high.
l
If the ambient temperature of the device is too high, go to
.
l
If the ambient temperature of the device is normal, go to
Step 4
Run the
fan speed
command to adjust the fan speed on the device to improve ventilation effect,
or add cooling equipment to ensure that the device works in a proper ambient temperature. Then,
check whether the fault is rectified.
l
If the fault is rectified, go to
l
If the fault persists, go to
.
Step 5
Check whether the board is properly installed.
l
If the board is properly installed, go to
.
l
If the board is not properly installed, install the board properly, and go to
Step 6
Check whether the fault is rectified.
l
If the fault is rectified, go to
l
If the fault persists, go to
.
Step 7
Replace the board with a new one, wait about five minutes, and then check whether the new
board repeatedly resets.
l
If the new board repeatedly resets, go to
l
If the new board does not repeatedly reset, go to
.
Step 8
Run the
display io-packetfile information
command to query the information about board
software packages in the flash memory and then check whether the information contains the
board software package information and whether its version is correct.
l
If the information contains the board software package information and its version is
correct, go to
.
l
If the information contains no board software package information or its version is
incorrect, go to
SmartAX MA5612 Multi-service Access Module
Maintenance Guide
6 System Fault Handling
Issue 01 (2012-07-25)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
236