Possible Cause
Judgment Criterion
Troubleshooting Method
A branch fiber break
occurs.
1. Check the branch fiber by
using the OTDR. It is found
that a branch fiber break
occurs.
2. Check the optical fiber on
site. It is found that the
optical fiber is broken or not
connected.
Reconnect the branch optical
fiber.
Step 3
Check for the possible causes on the ONU and troubleshoot the faults accordingly. If the ONU
still fails to be auto discovered by the OLT after that, proceed to
Possible Cause
Judgment Criterion
Troubleshooting Method
The ONU is not powered
on.
Check the power supply of the
ONU. It is found that the power
supply of the ONU fails or is
turned off.
Restore the power supply of the
ONU.
The ONU hardware is
faulty.
If either of the following two
situations occurs, the ONU
hardware is faulty.
l
The LEDs of the ONU are
off when the ONU is
powered on.
l
After the ONU is replaced
with another ONU, the new
ONU is auto discovered by
the OLT.
Replace the faulty ONU or the
optical module of the ONU.
SmartAX MA5612 Multi-service Access Module
Maintenance Guide
6 System Fault Handling
Issue 01 (2012-07-25)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
223