1.
On the MA5612, run the
display multicast flow-statistic ip 224.1.1.1 vlan 3
command to
query the traffic statistics of the ordered program on the upstream port (assume that the
MVLAN ID is 3 and the IP address of the multicast program is 224.1.1.1). If the queried
program traffic is not 0, the program traffic reaches the MA5612 upstream port.
2.
Run the
display statistics service-port
command two or three times to query the traffic
statistics of the service port to which the multicast user belongs. If values of
Number of
downstream packets
different greatly, the program traffic reaches the MA5612 user port.
NOTE
The following prerequisites must be met before you run the
display statistics service-port
command
to query the traffic statistics so as to prevent the queried results from being affected by other services.
l
The multicast user is not watching other programs.
l
The service port does no carry other heavy-traffic services. For example, the service of
downloading files from the Internet.
3.
According to the preceding queried results, determine the fault scope by referring to
and perform operations accordingly.
NOTE
When multiple NEs need to be checked, generally locate the fault from lower-layer devices to upper-
layer devices, that is, in the sequence of user terminal -> MA5612 -> multicast router -> multicast
server from segment to segment.
Table 4-5
Fault scope and troubleshooting method
Fault Scope
Judgment Criterion
Troubleshooting Method
User terminal
If the following symptoms
occur, the fault is because the
user terminal is faulty.
l
Multicast streams reach the
user port of the MA5612.
l
Other users of the MA5612
can watch the program.
Check the user terminal
following
User terminal and
MA5612
Multicast streams reach the
upstream port of the MA5612
but do not reach the user port.
a. Check the user terminal
following
.
b. Check the MA5612
following
.
User terminal,
MA5612, and
upper-layer
network and
devices of the
MA5612
Multicast streams do not reach
the upstream port of the
MA5612.
a. Check the user terminal
following
.
b. Check the MA5612
following
.
c. Check the upper-layer
network and devices
following
.
Step 2
Check the user terminal.
1.
Verify that the TV cable is properly connected to the STB.
SmartAX MA5612 Multi-service Access Module