![HPE StoreOnce 3620 Скачать руководство пользователя страница 135](http://html1.mh-extra.com/html/hpe/storeonce-3620/storeonce-3620_installation-manual_2175897135.webp)
c.
In the
Security
section, click the
Key Manager
panel.
d.
On the
Key Manager
screen, select Backup on the
Actions
menu (
).
Find Key Manager information in the
StoreOnce Management Console Online Help
, and in the
StoreOnce 3620, 3640, 5200, 5250, and 5650 Systems User Guide: For StoreOnce software version
4.1.0
.
3.
If using HPE StoreOnce Remote Support, disable remote event reporting to HPE. See
maintenance mode when using StoreOnce Remote Support
.
Enabling maintenance mode when using StoreOnce Remote Support
If StoreOnce Remote Support is configured, put the StoreOnce System into maintenance mode before
installing the upgrade. Enabling maintenance mode prevents the system from generating unwanted
support calls during the installation process.
Procedure
1.
Navigate to the StoreOnce System and log in to the StoreOnce Management Console.
2.
On the main menu, select
Settings
.
3.
In the
System
section, select the
Maintenance mode
panel.
4.
On the
Maintenance mode
screen, set the
Maintenance mode
switch to the
On
position (
),
and then click
OK
.
Powering down the StoreOnce System
Powering down the StoreOnce System using the StoreOnce Management Console, iLO or the front panel
Power On/Standby button does not completely shut off system power. Portions of the power supply and
some internal circuitry remain active.
Prerequisites
Log in with administrator privileges to perform this task.
Procedure
1.
Log in to the StoreOnce Management Console.
2.
On the main menu, select
Settings
.
3.
On the
Settings
screen, select
Shutdown
on the
Actions
menu (
).
Removing cables, extending the server from the rack, and removing the
access panel
StoreOnce Systems may have Capacity Upgrade Kits attached. StoreOnce 5200, StoreOnce 5250, and
StoreOnce 5650 Systems will have disk enclosures attached.
WARNING:
To reduce the risk of personal injury or equipment damage, be sure that the rack is
adequately stabilized before extending a component from the rack.
Installing optional hardware
135