Vendor
—HPE
•
Serial Number
—Library serial number
•
Robotic Hardware Revision
•
Barcode Reader Hardware Revision
•
Product ID
—MSL3040
•
Base Firmware Revision
—Version of the currently installed base module firmware
•
Expansion Firmware Revision
—Version of the currently installed expansion module firmware
•
Robotic Firmware Revision
—Version of the currently installed robotic assembly firmware. The
robotic assembly firmware is bundled and installed with the library firmware.
•
Barcode Reader Firmware Revision
—Version of the currently installed barcode reader firmware.
The barcode reader firmware is bundled and installed with the library firmware.
Library status
•
Library Status
◦
Idle
—The library robotic is ready to perform an action.
◦
Moving
—The library robotic is moving a cartridge.
◦
Scanning
—The library robotic is performing an inventory of cartridges.
◦
Offline
—The library robotic has been taken off line by the library.
•
Cartridge in Transport
—When applicable, displays the barcode label of the cartridge currently in the
robotic assembly
•
Total Power On Time
—Total time that the base module has been powered on since it was
manufactured
•
Odometer
—Robotic assembly move count
•
Robotic Location
—The module where the robotic assembly is currently located. The home location
for the robotic assembly is in base module behind the OCP.
•
Shipping Lock
—The shipping lock is part of the robotic assembly. Under normal operation, the library
will lock and unlock the shipping lock as needed when the robotic assembly is in the base module. For
instructions on locking or unlocking the shipping lock manually, see the user guide.
Module status
•
Base Controller Revision
or
Module Controller Revision
—Hardware revision of the controller
board currently installed in the module.
•
Power Supply Status
—Displays the status of power redundancy.
•
Lower Power Supply Fan
—Displays the status of the lower power supply fan. If a fan is not operating
correctly, the library generates a warning event.
•
Upper Power Supply Fan
—Displays the status of the upper power supply fan. If a fan is not
operating correctly, the library generates a warning event.
•
Drive Power Board Status
—Status of the drive power board (DC-DC converter) for the drive slots in
the module.
Operating the library
111