Table 16: Data Verification problems
Problem
Solution
A tape drive used for Data
Verification does not report an IP
address.
• Verify that Ethernet port on the tape drive is connected to the
same private network as the library DIAG port.
• Verify that only the library DIAG port and drives in the DVP
partition are connected to the private network. No other drives or
other devices may be connected to the private network.
The library appears unable to
communicate with one of the
Data Verification drives.
Verify that none of the tape drives in the DVP partition has an FC or
SAS port cabled. The drives used for Data Verification should only
have an Ethernet cable connected.
The library reports the drive
status for one of the Data
Verification drives as
“configuration failed.”
The library cannot perform an
operation with one of the Data
Verification drives, such as
pulling a support ticket or moving
media to or from the drive.
Command View TL cannot
authenticate to the library
• Verify that the passwords are the same in the RMI and Command
View TL GUI.
• Verify that DV is enabled in the RMI.
Command View TL does not
pass the connectivity test
• Verify that SNMP is enabled on the library.
• Check the network connections between the library and
Command View TL management station.
The library does not power on
Symptom
The library does not power on.
Action
1.
Check all power cord connections.
2.
Check the LEDs on the power supplies.
3.
Make sure that the power button on the front panel has been pressed, and the green
Ready
LED is
illuminated.
170
The library does not power on