NOTE:
Use extreme caution to prevent damaging other parts of the module.
A new spooling cable is provided with the replacement robotic assembly.
4.
Remove the expansion module containing the robotic assembly while carefully guiding the free
spooling cable; see
Preparing to remove the robotic assembly and spooling mechanism
on
page 153. While there may be minor differences, these instructions for a base module will also apply
to an expansion module.
5.
Remove the robotic assembly from the expansion module. See the initial steps in
robotic assembly and spooling mechanism from the base module
on page 154.
6.
Replace the expansion module in the rack; see
Installing the base module in the rack
on page 34.
While there may be minor differences, these instructions for a base module will also apply to an
expansion module.
7.
Remove the base module from the rack.
8.
Remove the spooling mechanism from the base module using the next set of steps in
robotic assembly and spooling mechanism from the base module
on page 154.
9.
Install the new robotic assembly and spooling mechanism; see
Installing the robotic assembly and
spooling mechanism into the base module
on page 156.
10.
Replace the base module in the rack; see
Completing the robotic assembly and spooling
on page 158.
The cabling and alignment instructions also apply to the expansion module that was removed.
Clearing obstructions from the library
For proper operation, the robotic assembly must be able to reach the bottom of the library.
Procedure
1.
Power off the library by pressing the front power button for 5 seconds and then select the
Default Park
Location
.
The library will park the robotic assembly in the base module behind the OCP.
2.
Remove the left magazine from the lowest library module.
For instructions on using the manual magazine release, see
Unlocking a magazine with the manual
182