![HP StoreEver MSL3040 Скачать руководство пользователя страница 214](http://html.mh-extra.com/html/hp/storeever-msl3040/storeever-msl3040_users-and-service-manual_2175305214.webp)
Event
code
Message text and description
Details and solution
2083
The drive power board is not compatible
with this library and does not match the
installed power supply.
The library supports different drive power board
and power supply revisions. Replace the drive
power board or power supplies in the module to
have a consistent set of components.
2084
Lost connection to module, possibly due
to abnormal network activity.
1.
Ensure that all modules are powered on.
2.
Verify that all module interconnect cables
are properly installed.
3.
If this event is seen on multiple modules,
ensure that the network that the base
module is connected to is not experiencing
broadcast storms or other abnormal activity.
4.
Reboot or power cycle the library to
rediscover the modules.
2085
Communication failure to the base
module controller board I2C port
expander component.
While this error persists, the base module is not
able to discover any of the attached expansion
modules.
1.
Reboot the library to see if the error persists.
2.
If the error persists, power off the library and
then reseat the base module controller.
3.
If the error continues to persist, replace the
base module controller.
2086
Communication failure to the expansion
module controller board I2C port
expander component.
While this error persists, the base module is not
able to discover any of the attached expansion
modules.
1.
Reboot the library.
2.
If the error persists, power off the library and
then reseat the expansion module controller.
3.
If the error continues to persist, replace the
expansion module controller.
Table Continued
214
Event codes