Event
code
Message text and description
Details and solution
2022
Drive has been hot removed while in
active status as LUN master. Tape drives
must be powered off before removing
them from the library.
Reinsert the removed drive in the same position
from which it was removed.
2023
Internal software error.
Reboot the library.
2024
Exception thrown by application not
handled.
An unrecoverable error occurred. Retry the
operation and if the error persists reboot the
library.
2025
Move failure due to vertical robotic
positioning problem.
1.
Check for obstructions, such as a cartridge
sticking out, in the vertical pathway of the
robotics assembly.
2.
Verify that the robotic assembly is aligned
and level within the library.
3.
Verify that the rack is level front to back and
side to side.
4.
Clear any obstructions from the bottom of
the library. For instructions, see
on page 182.
2026
Failed moving the robot towards the
back or front of the library.
Check for obstructions, such as a cartridge
sticking out or cable impeding progress, in the
horizontal pathway of the robotics assembly.
2027
Move failed pulling cartridge from slot.
• Inspect the cartridge and cartridge labels for
physical damage that could prevent the
cartridge from being inserted into or
removed from the slot.
• Clear any obstructions from the bottom of
the library. For instructions, see
2028
Move failed inserting cartridge to slot.
Table Continued
Event codes
201