+5 volts
Crossed lower critical
Web:
YES Critical
LCD: YES
Also display voltage
icon
Status Light: Flashing
YELLOW
+5 volts Crossed lower critical
Please click on the URL below to
get details
Help configuring thresholds for
+5 volts
If +5V voltage falls below
4.7V, then system
performs an automatic
shutdown!
+5 volts
Back to Normal
Web:
YES Warning
LCD: YES
Status Light: GREEN
+5 volts Back to Normal
Please click on the URL below to
get details
Help configuring thresholds for
+5 volts
Automatically cleared after
5 seconds
+3.3 volts
Crossed upper
noncritical
Web:
YES Warning
LCD: YES
Also display voltage
icon
Status Light: Flashing
YELLOW
+3.3 volts Crossed upper
noncritical
Please click on the URL below to
get details
Help configuring thresholds for
+3.3 volts
User-initiated via detailed
message page, or
Automatically cleared
when power supply
auto-adjusts to correct
problem
+3.3 volts
Crossed upper critical
Web:
YES Critical
LCD: YES
Also display voltage
icon
Status Light: Flashing
YELLOW
+3.3 volts Crossed upper critical
Please click on the URL below to
get details
Help configuring thresholds for
+3.3 volts
If +3.3V voltage rises
above 3.5V, then system
performs an automatic
shutdown!
+3.3 volts
Crossed lower
noncritical
Web:
YES Warning
LCD: YES
Also display voltage
icon
Status Light: Flashing
YELLOW
+3.3 volts Crossed lower
noncritical
Please click on the URL below to
get details
Help configuring thresholds for
+3.3 volts
User-initiated via detailed
message page, or
Automatically cleared
when power supply
auto-adjusts to correct
problem
Troubleshooting, Alert Messages
file:///D|/ADMIN_~1/eng/trouble/alerts.htm (20 of 23) [5/3/2000 3:34:45 PM]