-12 volts
Crossed lower critical
Web:
YES Critical
LCD: YES
Also display voltage
icon
Status Light: Flashing
YELLOW
-12 volts Crossed lower critical
Please click on the URL below to
get details
Help configuring thresholds for
-12 volts
If -12V voltage rises above
-10.56V, then system
performs an automatic
shutdown!
-12 volts
Back to Normal
Web:
YES Warning
LCD: YES
Status Light: GREEN
-12 volts Back to Normal
Please click on the URL below to
get details
Help configuring thresholds for
-12 volts
Automatically cleared after
5 seconds
+5 volts
Crossed upper
noncritical
Web:
YES Warning
LCD: YES
Also display voltage
icon
Status Light: Flashing
YELLOW
+5 volts Crossed upper noncritical
Please click on the URL below to
get details
Help configuring thresholds for
+5 volts
User-initiated via detailed
message page, or
Automatically cleared
when power supply
auto-adjusts to correct
problem
+5 volts
Crossed upper critical
Web:
YES Critical
LCD: YES
Also display voltage
icon
Status Light: Flashing
YELLOW
+5 volts Crossed upper critical
Please click on the URL below to
get details
Help configuring thresholds for
+5 volts
If +5V voltage rises above
5.3V, then system
performs an automatic
shutdown!
+5 volts
Crossed lower
noncritical
Web:
YES Warning
LCD: YES
Also display voltage
icon
Status Light: Flashing
YELLOW
+5 volts Crossed lower noncritical
Please click on the URL below to
get details
Help configuring thresholds for
+5 volts
User-initiated via detailed
message page, or
Automatically cleared
when power supply
auto-adjusts to correct
problem
Troubleshooting, Alert Messages