Specification
Value
Rated input frequency
50 Hz to 60 Hz
Not applicable to 240 VDC
Rated input current
5.6 A at 100 VAC
2.7 A at 200
VAC
2.3 A at 240 VDC for China only
Maximum rated input power
557 W at 100 VAC
539 W at 200 VAC
537 W at 240 VDC for China only
BTUs per hour
1902 at 100 VAC
1840 at 200 VAC
1832 at 240 VDC for China only
Power supply output
—
Rated steady-state power
500 W at 100 VAC to 127 VAC input
500 W at 100 VAC to 240 VAC input
500 W at 240 VDC input for China only
Maximum peak power
500 W at 100 VAC to 127 VAC input
500 W at 100 VAC to 240 VAC input
500 W at 240 VDC input for China only
HPE 800W Flex Slot Platinum Hot-plug Low Halogen Power Supply
Specification
Value
Input requirements
—
Rated input voltage
100 VAC to 127 VAC
200
VAC to 240
VAC
240 VDC for China only
Rated input frequency
50 Hz to 60 Hz
Not applicable to 240 VDC
Table Continued
Specifications
175
Содержание HPE ProLiant DX360 Gen10
Страница 7: ...Regulatory information 183 Documentation feedback 184 Acronyms and abbreviations 185 7 ...
Страница 44: ...Operations 44 ...
Страница 74: ...8 Route and connect the data cable 9 Route and connect the power cable Hardware options installation 74 ...
Страница 101: ... Full length Hardware options installation 101 ...
Страница 107: ... 10 SFF SAS SATA NVMe Combo 4 LFF Hardware options installation 107 ...
Страница 125: ...8 Using a Torx T 10 screwdriver remove the Power UID USB assembly 8 SFF 4 LFF Hardware options installation 125 ...
Страница 129: ...6 Install the 4 LFF display port USB module 7 Route and connect the cable Hardware options installation 129 ...
Страница 150: ...2 SFF backplane to P816i a controller 10 SFF NVMe backplane to NVMe riser Cabling 150 ...
Страница 151: ...2 SFF NVMe backplane to primary riser 1 SFF rear backplane to system board SATA Cabling 151 ...