Contents
GC does not turn on, 68
MSD does not turn on, 68
Foreline pump is not operating, 68
Fan for the high vacuum pump is not operating, 69
MSD is on but the status LEDs are all blinking, 69
MSD turns on but then the foreline pump shuts off, 69
Passes tune, 70
Does not pass tune, 71
Peaks are tailing, 71
Peaks are fronting, 71
Peaks have flat tops, 72
Peaks have split tops, 72
Baseline is rising, 72
Baseline is high, 72
Baseline is falling, 72
Baseline wanders, 73
Retention times for all peaks drift – shorter, 73
Retention times for all peaks drift – longer, 73
Poor sensitivity, 74
Poor Repeatability, 74
Isotopes are missing or isotope ratios are incorrect, 75
High background, 75
High abundances at m/z 18, 28, 32, and 44 or at m/z 14 and 16, 75
Mass assignments are incorrect, 76
Peaks have precursors, 76
Peak widths are inconsistent, 76
Relative abundance of m/z 502 is less than 3%, 77
Spectra look different from those acquired with other HP MSDs, 77
High mass sensitivity is poor, 78
Foreline pressure is too high, 79
Vacuum manifold pressure is too high, 79
Foreline pressure is too low, 80
Vacuum manifold pressure is too low, 80
Gauge controller displays 9.9+9 and then goes blank, 80
Power indicator on the gauge controller does not light, 81
Содержание 5973
Страница 1: ...H Hardware Manual HP 5973 Mass Selective Detector ...
Страница 3: ...HP 5973 Mass Selective Detector Hardware Manual ...
Страница 25: ...1 Installing GC Columns To condition a capillary column 25 ...
Страница 30: ...30 ...
Страница 37: ...2 Operating the MSD To view MSD analyzer temperature and vacuum status 37 ...
Страница 39: ...2 Operating the MSD To set monitors for MSD temperature and vacuum status 39 ...
Страница 41: ...2 Operating the MSD To set the MSD analyzer temperatures 41 ...
Страница 43: ...2 Operating the MSD To set the interface temperature from the ChemStation 43 ...
Страница 51: ...2 Operating the MSD To remove the MSD covers 51 Upper cover Lower cover ...
Страница 92: ...92 ...
Страница 103: ...4 Maintaining the MSD To check and add foreline pump oil 103 Lower line Oil level window Fill cap Upper line ...
Страница 105: ...4 Maintaining the MSD To drain the foreline pump 105 Fill cap Drain plug Pump motor ...
Страница 107: ...4 Maintaining the MSD To refill the foreline pump 107 Fill cap Upper line Oil level window Drain plug ...
Страница 109: ...4 Maintaining the MSD To replace the oil trap 109 Oil trap Clamp O ring assembly Oil trap adapter Foreline pump ...
Страница 111: ...4 Maintaining the MSD To check the diffusion pump fluid 111 Fan Fluid level window sight glass ...
Страница 113: ...4 Maintaining the MSD To separate the MSD from the GC 113 ...
Страница 121: ...4 Maintaining the MSD To reconnect the MSD to the GC 121 ...
Страница 123: ...4 Maintaining the MSD To remove the calibration vial 123 Calibration valve Collar Calibration vial ...
Страница 125: ...4 Maintaining the MSD To refill and reinstall the calibration vial 125 Calibration valve Collar Calibration vial 6 mm ...
Страница 141: ...4 Maintaining the MSD To lubricate the side plate O ring 141 Side plate O ring ...
Страница 159: ...4 Maintaining the MSD To remove a filament 159 Filament 2 Filament 1 ...
Страница 161: ...4 Maintaining the MSD To reinstall a filament 161 Filament 2 Filament 1 ...
Страница 210: ...210 ...
Страница 211: ...6 GC MSD Interface This chapter describes the function of the GC MSD interface GC MSD interface 212 ...
Страница 214: ...214 ...
Страница 232: ...232 7 Analyzer Analyzer heaters and radiators ...
Страница 280: ...280 ...
Страница 294: ...294 Index ...
Страница 296: ...294 Chapter ...
Страница 297: ...H Manual Part Number G1099 90027 Copyright 1998 Hewlett Packard Printed in USA 11 98 ...