CM4 Four-Point Continuous Monitor
CM4 Technical Manual
D-3
Printer Share Boxes
Instrument Inputs
Operating Voltage
Part Number
6
120 VAC
1874-0007
6
230 VAC
1874-0008
11
120 VAC
1874-0010
11
230 VAC
1874-0011
Table D-1: Printer Share Box Part Numbers
NOTE:
Cabinets supplied by Honeywell Analytics include a transformer to
convert customer-supplied power to 120 VAC. For these installations,
share box 1874-0007 or 1874-0010 should be used.
D.2 Jumpers
The jumpers on the 874021-R printer option board are factory-set for
either single CM4 monitor to printer or multiple CM4 monitor to printer
share box applications.
For single CM4 monitors connected directly to the printer, jumpers C,
D, E, and F are used. For multiple CM4 monitors, jumpers A, B, G,
and H are used, as shown below:
C4
C3
J2
C1
mda scientific
C5
C7
H
G
F
E
D
C
B
A
LS1
C2
C6
U1
+
+
+
+
+
+
C8
5
1
1
9
874270
REV
J1
Serial Communications Interface Board.
For single CM4 monitors connected directly
to an optional printer, the jumpers are set
in positions C, D, E and F. This configures the CM4
as data communications equipment (DCE)
Figure D-1: 874021-R Single CM4 Printer Connections
C4
C3
J2
C1
mda scientific
C5
C7
H
G
F
E
D
C
B
A
LS1
C2
C6
U1
+
+
+
+
+
+
C8
5
1
1
9
874270
REV
J1
Serial Communications Interface Board.
For multiple CM4 monitors connected to
a printer share box option, the jumpers are
set in positions A, B, G and H. This configures
the CM4 as data terminal equipment (DTE).
Figure D-2: 874021-R Multiple CM4 Printer Connections
珠海司福斯特科技有限公司