Galaxy 3 Series Programming Manual
65
51 - Parameters (cont’d)
47 = Set Confirm
This parameter allows the system to emit a short double beep when the system/group has set. There are three
options.
0 = Off
No indication
1 = Alert on Set
A double beep when the system has set
Alert on Comm
A double beep after a successful signal to the ARC that setting has occurred.
48 = Alarm Limits
This parameter allows the user to program the maximum number of alarms, per group, which may be transmit-
ted to an Alarm Receiving Centre in any set period. There are three options:
1 = No of Alarms
This is the total number of zone activations logged in any one set period. The selectable values are
0-10
where
0
is unlimited.
2 = Unset Limit
This is the number of activations logged from any one zone in any one unset period. The selectable values are
0-7.
The default is
3
. Fire and PA alarms are not restricted by this parameter.
3 = Set Limit
This is the number of activations logged from any one zone in any one set period. The selectable values are
0-
7.
The default is
3
.
Fire and PA alarms are not restricted by this parameter.
NOTE:
This feature only affects Contact ID, SIA and Microtech communication formats.
Содержание 3-144
Страница 1: ...Honeywell Security Galaxy 3 48C 3 144 3 144C 3 520 3 520C Programming Manual ...
Страница 2: ......
Страница 8: ...Galaxy 3 Series Programming Manual 2 ...
Страница 30: ...Galaxy 3 Series Programming Manual 24 ...
Страница 184: ...Galaxy 3 Series Programming Manual 178 ...
Страница 188: ...Galaxy 3 Series Programming Manual A 4 ...
Страница 202: ...Galaxy 3 Series Programming Manual C 2 ...
Страница 212: ...2 Galaxy 3 Series Programming Manual ...
Страница 213: ...3 Galaxy 3 Series Programming Manual ...