Galaxy 3 Series Programming Manual
79
13 PA
The
PA
(Personal Attack) function is continuously operational. Activation of this zone type overrides the
Bell
Delay
parameter and causes an instant full alarm condition that requires to be reset with a code authorized for
PA Reset
— refer to
Option
51 – PARAMETERS, 22 = PA Reset
; the
Intruder
outputs are not acti-
vated by
PA
zones.
NOTE:
If a
PA
zone is open, it is indicated on the keypad whenever a valid code is entered. The group that
the open
PA
is assigned to cannot be set until it is closed.
14 PA Silent
The
PA Silent
function is identical to the
PA
function, with the exception that there is no audible or visual
indication of the activation; that is, no bells or strobes are activated. Only the
PA
output (normally channel 2
on the digital communicator) signals the alarm. The activation (
+
) and restoral (–) of
PA Silent
zones is
recorded in the event log.
NOTES
1.
At the time of setting, any
PA Silent
zones that are currently open are reported to the user.
2.
The tamper facility on the
PA
zone remains active while engineer mode is accessed.
3.
Engineer mode cannot be exited if a
PA Silent
zone is open.
15 PA Delay
The
PA Delay
function is identical to the
PA
function, with the exception that the
PA
output activation can be
delayed for up to 60 seconds; this is determined by option
51.13 = PARAMETER.PA Delay
. During the
period of delay the
Entry/Exit Horns
activate to remind the user that the PA delay is counting down; entering
a valid code or closing the
PA Delay
zone aborts the alarm.
NOTES
1.
If a
PA Delay
zone is open, it is indicated on the keypad whenever a valid code is entered. The group
that the open
PA Delay
is assigned to cannot be set until it is closed.
2.
The tamper facility on the
PA
zone remains active while engineer mode is accessed.
16 PA Delay Silent
The
PA Delay Silent
function is identical to the
PA Delay
function, with the exception that there is no audible
or visual indication of the activation; that is, no bells or strobes are activated. Only the
PA
output (normally
channel 2 on the digital communicator) signals the alarm. The activation (
+
) and restoral (–) of
PA Delay
Silent
zones are recorded in the event log.
NOTES
1.
At the time of setting, any
PA Delay Silent
zones that are currently open are reported to the user.
2.
The tamper facility on the
PA
zone remains active while engineer mode is accessed.
52 - Program Zones (cont’d)
Содержание 3-144
Страница 1: ...Honeywell Security Galaxy 3 48C 3 144 3 144C 3 520 3 520C Programming Manual ...
Страница 2: ......
Страница 8: ...Galaxy 3 Series Programming Manual 2 ...
Страница 30: ...Galaxy 3 Series Programming Manual 24 ...
Страница 184: ...Galaxy 3 Series Programming Manual 178 ...
Страница 188: ...Galaxy 3 Series Programming Manual A 4 ...
Страница 202: ...Galaxy 3 Series Programming Manual C 2 ...
Страница 212: ...2 Galaxy 3 Series Programming Manual ...
Страница 213: ...3 Galaxy 3 Series Programming Manual ...