Galaxy 3 Series Programming Manual
84
38 PA Unset
This
PA Unset
function is identical to the
PA Silent
function, with the exception that it is only operational
when the system is unset; the function is inactive when the group is set.
39 Keyswitch Reset
The
Keyswitch Reset
function allows alarms to be cancelled and the system to rearm without unsetting the
Galaxy. The type of reset authorization is determined by the
Keyswitch Level
(option
51.14
). The type
required to reset
Intruder
,
PA
and
Tamper
alarms is determined by the
System Reset
,
Tamper Reset
and
PA Reset
parameters (option
51.06
,
51.07
and
51.22
) respectively.
This function is designed to permit a remote signal, for example REDCare’s Return Path Signalling feature, to
reset the system following an alarm condition.
40 Bell Fail
This zone type is intended for bells which have diagnostic capabilities and failure outputs. If activated, this zone
causes a fault condition.
41 Intr Low
This zone type assigns a low priority to a zone in the event of an intruder alarm. The event is logged as low
priority in the event log.
42 Intr High
This zone type assigns a high priority to a zone in the event of an intruder alarm. The event is logged as high
priority in the event log.
43 PSU Fault
This zone type triggers a general fault output and logs a PSU fault in the event log. The fault is signalled to the
ARC as
YP
when using SIA format and
314
when using CID format.
44-46
Not used
47 Vibration
The
Vibration
function is continuously operational and is designed for use with vault sensors.
Vibration
zones can be block omitted using menu option
11 = Omit Zones
. If the zone selected to be omitted from the
system is a
Vibration zone
, then all zones programmed with this function are omitted.
NOTES
1.
All
Vibration
zones in all groups are omitted when any
Vibration
zone is omitted. The user code does
not have to have access to all of the groups.
2. Vibration
zones remain omitted until a single
Vibration
zone is manually reinstated. The unsetting of the
system does not reinstate omitted
Vibration
zones.
52 - Program Zones (cont’d)
Содержание 3-144
Страница 1: ...Honeywell Security Galaxy 3 48C 3 144 3 144C 3 520 3 520C Programming Manual ...
Страница 2: ......
Страница 8: ...Galaxy 3 Series Programming Manual 2 ...
Страница 30: ...Galaxy 3 Series Programming Manual 24 ...
Страница 184: ...Galaxy 3 Series Programming Manual 178 ...
Страница 188: ...Galaxy 3 Series Programming Manual A 4 ...
Страница 202: ...Galaxy 3 Series Programming Manual C 2 ...
Страница 212: ...2 Galaxy 3 Series Programming Manual ...
Страница 213: ...3 Galaxy 3 Series Programming Manual ...