Galaxy 3 Series Programming Manual
157
2 = MAX Address
The address and the on-line or standalone status of the MAX Modules are assigned and modified using this
option. On selecting
MAX Address
the Galaxy searches for the MAX with the highest address. The Galaxy
48 prompts for the AB line (1-1); the Galaxy 144 prompts for the AB line (1-2); the Galaxy 520 prompts for
the AB line (1-4) that is to be searched. Select the line and press the
ent
key. On locating the MAX, the
keypad prompts for the
TYPE
of MAX to be assigned:
0 = On-Line
The MAX is fully integrated with the Galaxy system and communicates via the AB line,
sharing system resources and facilities
1 = Standalone
The MAX operates as an entirely independent unit. The Galaxy does not monitor the MAX
for alarms, tampers or power failure.
The MAX can then be readdressed. The keypad displays the current address of the MAX and the range of
valid addresses. All MAX modules default to address
7
, it is recommended that when adding MAX modules,
the first is redressed as
0
, the second as
1
and so on.
Enter the new MAX address and press the
ent
key; the Galaxy then reprograms the address of the MAX.
The keypad indicates the old and new MAX addresses and the status of the reprogramming.
When the reprogramming is complete the MAX bleeps and the display returns to
2 = MAX Address
.
3 = MAX Parameters
This option defines the individual operational features of each of the MAX/MicroMAX modules. On selecting
this option the address of the first MAX/MicroMAX on the system is displayed along with the descriptor
currently assigned to it. While the MAX/MicroMAX address is displayed on the keypad, the address pattern
on the MAX/MicroMAX module is indicated by the LEDs switching on. Pressing the # key displays a graphic
on the keypad which corresponds to the LED pattern on the MAX/MicroMAX module.
The following figure shows the graphic display for both a MAX and a MicroMAX address as 26.
63 - Options (cont’d)
The line numbers are represented by the top row in MAX and blocks 2
nd
and 3
rd
from the top in the
MicroMAX and the address numbers are represented by the bottom row of blocks in the MAX and the four
bottom blocks in the MicroMAX. The top LED on the MicroMAX is always off in this mode.
The combinations are shown in the following
Figure
:-
Figure 11. LED Status
Figure 12. Line Number/Module Address
Old address
New address
Status of
reprogramming
7 –> 0 [24]
7 –> 0 [24]
7 –> 0 [24]
7 –> 0 [24]
7 –> 0 [24]
2 6
M A X
2 6
M A X
MicroMAX LEDs Displayed
MAX LEDs Displayed
Bottom
Top (unused)
Line No.
Module Address
4
1
3
2
4
1
3
2
0
7
6
5
Содержание 3-144
Страница 1: ...Honeywell Security Galaxy 3 48C 3 144 3 144C 3 520 3 520C Programming Manual ...
Страница 2: ......
Страница 8: ...Galaxy 3 Series Programming Manual 2 ...
Страница 30: ...Galaxy 3 Series Programming Manual 24 ...
Страница 184: ...Galaxy 3 Series Programming Manual 178 ...
Страница 188: ...Galaxy 3 Series Programming Manual A 4 ...
Страница 202: ...Galaxy 3 Series Programming Manual C 2 ...
Страница 212: ...2 Galaxy 3 Series Programming Manual ...
Страница 213: ...3 Galaxy 3 Series Programming Manual ...