Galaxy 3 Series Programming Manual
60
26 = Forced
The
Forced
parameter enables or disables Menu option
14 = FORCED SET
. If the parameter is set to
1
(enabled) the user can force the system to set, automatically omitting any omittable zones that are open at the
time of setting. If the parameter is set to
0
(disabled), option
14 = FORCED SET
is not available to the user;
the message
Option not available
is displayed. The parameter defaults to
0
(disabled).
NOTE:
It is recommended that
Final
,
Entry
and
Push-Set
zones have the omit attribute disabled.
27 = CCT Debounce
The
cct Debounce
parameter determines the response time of the zones (how long they must remain open
before registering as changing state). The
cct Debounce
is programmable within the range
20–1000
millisec-
onds (
0.02–1
second); the default is 300 msecs. All entries are rounded up to the nearest 20 msecs.
NOTE:
The value programmed in this option is the value allocated to the SYSTEM selection when program-
ming zone response time in option 52.
28 = Online Print
This parameter is used to select the print mode required when connecting a serial printer to the Galaxy panel;
there are two options:
0 = disabled
(default): system only prints specific details at the user’s request. The printer can be
connected and disconnected at any time as required;
1 = enabled
: this option switches the printer to
on-line
mode and requires that a printer be
continuously connected to the system. Events are printed as and when they occur. The events printed
are controlled by parameter
29 = Online Level
.
NOTE:
If
Online Print
is enabled, the event log and other options will not be printed at the user’s request.
The parameter must be disabled to permit all other print options to operate.
29 = Online Level
The
On-line Level
parameter determines the level of events that are printed when parameter
28 = Online
is enabled:
0
(default) - basic print (setting, unsetting, alarms);
1
- full print excluding MAX events (setting, unsetting, alarms, modifications, technical
details)
2
- full print including MAX events (all logged events).
3
- MAX events only (only card events).
4
- Basic Print plus MAX events (option 0 + MAX events).
51 - Parameters (cont’d)
Содержание 3-144
Страница 1: ...Honeywell Security Galaxy 3 48C 3 144 3 144C 3 520 3 520C Programming Manual ...
Страница 2: ......
Страница 8: ...Galaxy 3 Series Programming Manual 2 ...
Страница 30: ...Galaxy 3 Series Programming Manual 24 ...
Страница 184: ...Galaxy 3 Series Programming Manual 178 ...
Страница 188: ...Galaxy 3 Series Programming Manual A 4 ...
Страница 202: ...Galaxy 3 Series Programming Manual C 2 ...
Страница 212: ...2 Galaxy 3 Series Programming Manual ...
Страница 213: ...3 Galaxy 3 Series Programming Manual ...