Galaxy 3 Series Programming Manual
78
If the system is set, operating a
Keyswitch
immediately unsets the assigned groups; there is no entry time
countdown.
The
Part
attribute of the
Keyswitch
function defaults to
0
(disabled); the standard
Keyswitch
function full
sets the system. To part set the system using the
Keyswitch
, the
Part
attribute must be enabled.
NOTE:
The operation of a
Keyswitch
zone can be extended to the setting and unsetting of multiple groups
by pressing the key when assigning a group to the zone. Refer to the
Star Group Function
.
The standard programming of the
Keyswitch
function requires a momentary change from 1k
Ω
to 2k
Ω
to
both set and unset the system. If the
Keyswitch
connected has a latching mechanism, press the key when
assigning the function; the display indicates
09= KEYSWITCH
has been assigned. The
Keyswitch
operation is as follows: 1k
Ω
to 2k
Ω
sets the system; 2k
Ω
to 1k
Ω
unsets the system.
The
Keyswitch
function can also be programmed to reset alarms - refer to option
51.14 =
PARAMETERS.Keyswitch Level
. If the
Keyswitch
is assigned a sufficient type to reset the alarm condi-
tion, the alarm is cancelled and immediately reset when the
Keyswitch
is used to unset the system following
an alarm activation.
NOTE:
The activated zones are not displayed on the keypad when a
Keyswitch
is used to reset the alarm.
10 Secure Final
This zone has dual functionality depending on whether the system is set or unset. When the system is setting,
set or unsetting the operation is identical to the
Final
zone function. When the system is unset the operation is
identical to the
Security
zone function.
Pressing the key when programming a
Secure Final
zone doubles the entry time of the group.
Opening a
Secure Final
zone during the exit time is not reported on the keypad as an open zone; the
Entry/
Exit Horns
bleep rapidly to indicate that the zone is open.
The termination feature of a
Secure Final
zone can be extended to terminate the setting of multiple groups by
pressing the key when assigning a group to the zone. Refer to the
Star
Group Function
.
11 Part Final
This zone has dual functionality depending on whether the system is full set or part set. When the system is full
set the zone operation is identical to the
Final
zone function. When the system is part set the zone operation is
identical to the
Intruder
zone function.
Pressing the
key when programming a
Part Final
zone doubles the entry time of the group.
Opening a
Part Final
zone during the exit time is not reported on the keypad as an open zone; the
Entry/Exit
Horns
bleep rapidly to indicate that the zone is open.
12 Part Entry
This zone has dual functionality depending on whether the system is full set or part set. When the system is full
set the zone operation is identical to the
Exit
zone function. When the system is part set the zone operation is
identical to the
Entry
zone function.
Pressing the key when programming a
Part Entry
zone doubles the entry time of the group.
52 - Program Zones (cont’d)
Содержание 3-144
Страница 1: ...Honeywell Security Galaxy 3 48C 3 144 3 144C 3 520 3 520C Programming Manual ...
Страница 2: ......
Страница 8: ...Galaxy 3 Series Programming Manual 2 ...
Страница 30: ...Galaxy 3 Series Programming Manual 24 ...
Страница 184: ...Galaxy 3 Series Programming Manual 178 ...
Страница 188: ...Galaxy 3 Series Programming Manual A 4 ...
Страница 202: ...Galaxy 3 Series Programming Manual C 2 ...
Страница 212: ...2 Galaxy 3 Series Programming Manual ...
Страница 213: ...3 Galaxy 3 Series Programming Manual ...