Galaxy 3 Series Programming Manual
108
56 - Communications (cont’d)
Channels 1-16
Each channel can be programmed with the following attributes:
1 = Output function
2 = Output mode
3 = Output Polarity
4 = Groups
1 = Output Function
Any of the system output functions (see option
53 = Program Outputs
) can be assigned to each of the
channels 1 – 16. Channel 3 defaults to output function
04 = INTRUDER
. All other channels default to
11=SPARE
. Select the required output function using the
A
and
B
keys or by entering the function
number directly. Once the required function is displayed, press the
ent
key to assign the function to the
selected channel. For example, a
PA
function programmed on channel 2 results in a
PA
code to be trans-
mitted on channel 2 to the ARC when there is a
PA
alarm activation.
Confirmed alarm conditions will now work across multiple groups. Previously, a confirmed condition
would only be created if both zones activated were in the same group. Confirmed outputs (and channels
in DTMF format,
option 56.1.1.1
) will activate for alarms across groups as long as both groups con
cerned have been assigned to that output or channel.
2 = Output Mode
Each output function defaults to a specific, logical output mode. However, the output mode of each func-
tion can be modified to meet special requirements: when reprogrammed, the new mode applies to all
outputs assigned to that function. The output modes are:
1
= Latch:
the output remains active until a valid code is entered,
2 =
Reflex:
the output follows the activity of the triggering event, for example, the Set output follows the
setting and unsetting of the group.
3
= Pulse:
the output remains active for the programmed pulse time (1-300 seconds).
Programming the Output Mode
Select the required mode using the
A
or
B
keys or by selecting the number
1 - 3
. Once the required mode
is selected, press the
ent
key to accept the programming. If assigning the
Pulse
output mode, enter the
pulse time (001 – 300 seconds) and press the
ent
key.
NOTE:
The
Output Mode
status determines the operation of the channel restore. The status is modified
by pressing the key when the channel details display on the keypad. The status options are:
= Restore – channel sends restore code when reset
+
= Open/close - channel reports setting/unsetting
blank
= Alarm only - channel signals alarm only (no restore signal transmitted)
3 = Output Polarity
The
Output Polarity
determines the normal operational state of the output.
0
= POS - channel activates when the output is triggered.
1
= NEG - channel activates when the output is reset.
Содержание 3-144
Страница 1: ...Honeywell Security Galaxy 3 48C 3 144 3 144C 3 520 3 520C Programming Manual ...
Страница 2: ......
Страница 8: ...Galaxy 3 Series Programming Manual 2 ...
Страница 30: ...Galaxy 3 Series Programming Manual 24 ...
Страница 184: ...Galaxy 3 Series Programming Manual 178 ...
Страница 188: ...Galaxy 3 Series Programming Manual A 4 ...
Страница 202: ...Galaxy 3 Series Programming Manual C 2 ...
Страница 212: ...2 Galaxy 3 Series Programming Manual ...
Страница 213: ...3 Galaxy 3 Series Programming Manual ...