Option 31 – Walk Test (Quick Menu Option 6)
The
Walk Test
option offers two methods of testing zones.
1.
Test All Zones
: This option initiates a walk test that includes all zones that have the omit attribute
enabled (refer to option
52 = PROGRAM ZONES
). When selected, the walk test starts immediately. The
message
NO ENTRIES
is displayed if all zones are non-omittable when selecting All Zones. Non-omittable
zones are not included in this test and remain active throughout the test.
2.
Selected Zones:
This test option allows the user to select any zones, irrespective of function type, for
walk testing. As many zones as necessary may be added to the list before starting the test. On entering this
option the details of the first zone are displayed. Each zone required for test can be selected using the A or B
keys or by entering the zone number. Press the # to toggle the test status of each zone in the Walk Test: the
test status of the zone changes to TEST if it is included in the test and # = TEST if it is not. When all the
required zones have been selected, press the ent key to start the walk test.
Press the key to include all zones in the Selected Zones walk test, without having to individually select the
zones. Once all zones are selected, the # key can be used to remove selected zones from the test.
NOTE: PA, PA Silent, PA Delay, PA Silent Delay
and
Fire
are not included in the test when the key is
used to include all zones.
The response times of the zone circuits are reduced to 20 msecs (40 msecs for RF RIO’s) for the duration of
the walk test to facilitate the detection of loose connections or damaged wiring.
Once the walk test has started, opening a zone (or a zone that is open at the start of the test) activates outputs
programmed as
Entry/Exit Horn
. If a single zone is open, the keypad displays the address and function of
the zone. If multiple zones are open, then the keypad indicates how many zones are open; the open zones can
be viewed by pressing the
A
or
B
keys.
NOTE:
The
Walk Test
option does not display the status of the zones. If an open zone is included in the
walk test, the
Entry/Exit Horn
will activate as soon as the test is started and remains active until the
zone is closed.
While the walk test is active the message
WALK TEST ACTIVE / ESC to abort
is displayed; press the
#
key to view all zones that have been walk tested so far. To return to the walk test press the # key again.
NOTE:
RF zones will also record the signal strength in reduced gain mode.
Ending the Walk Test
To terminate the walk test, press the
esc
key. The test will terminate automatically if no zones are activated for
20 minutes.
The results of the test can be viewed by accessing the event log (refer to option
22 = DISPLAY LOG
). The
start of the walk test is indicated by the display
WALK TEST +
; each zone that was tested is recorded (the
activation of each zone is recorded only once during the test — even if it was opened several times); the end
of the test is indicated by
WALK TEST –
.
31 - Walk Test
Содержание 3-144
Страница 1: ...Honeywell Security Galaxy 3 48C 3 144 3 144C 3 520 3 520C Programming Manual ...
Страница 2: ......
Страница 8: ...Galaxy 3 Series Programming Manual 2 ...
Страница 30: ...Galaxy 3 Series Programming Manual 24 ...
Страница 184: ...Galaxy 3 Series Programming Manual 178 ...
Страница 188: ...Galaxy 3 Series Programming Manual A 4 ...
Страница 202: ...Galaxy 3 Series Programming Manual C 2 ...
Страница 212: ...2 Galaxy 3 Series Programming Manual ...
Страница 213: ...3 Galaxy 3 Series Programming Manual ...