04 Receiver
The transmission destination can be set to one of three modes:
1 = Single
Reports to the telephone number programmed in
Telephone Number 1.
2 = Dual
Reports to both numbers programmed in
Telephone Number 1
and
Telephone Number 2
. The alarm must
be transmitted to both numbers.
3 = Alternate
Reports to
Telephone Number 1
OR
Telephone Number 2
. Each number is tried in sequence until the
alarm is successfully transmitted. The alarm is only transmitted to one number. Telephone number 1 is always
the first number attempted.
05 Telephone No. 2
A second telephone number is available to support
Dual
and
Alternate
dialling to a second destination
receiver. The programming is identical to
Telephone Number 1
.
The
B
key is used to erase an existing number. Each press deletes the last digit displayed.
06 Dial Type
The transmission mode can be selected from two types:
1. Tone
(also known as “DTMF Dial”) this is much quicker at dialling than the
Pulse
option.
2. Pulse
(also known as “Rotary” or “Loop Disconnect”) is universal, however, an increasing number of
exchanges now provide the Tone (DTMF Dial) option.
NOTE:
If unsure of the type of exchange that the panel is connected to, leave as
Pulse
dialling.
07 Autotest
An engineer test can be automatically transmitted to the Monitoring Station at programmed intervals, in order
to indicate alarm transmission path integrity.
1 = Start Time
The engineer uses this option to enter the time that the first engineer test is transmitted. Subsequent engineer
test transmissions are offset by the value assigned in the
Test Interval
option.
2 = Intervals
This option determines the period between engineer test transmissions following the
Start Time
, the program-
mable range is
0 – 99
hours.
NOTES:
1.
If the
Test Interval
is
0
(default) the
Autotest
is disabled — even if a
Start Time
has been assigned.
2.
To disable
Autotest
enter
00:00
(default); no transmissions of test signals can be sent at midnight.
56 - Communications (cont’d)
Содержание 3-144
Страница 1: ...Honeywell Security Galaxy 3 48C 3 144 3 144C 3 520 3 520C Programming Manual ...
Страница 2: ......
Страница 8: ...Galaxy 3 Series Programming Manual 2 ...
Страница 30: ...Galaxy 3 Series Programming Manual 24 ...
Страница 184: ...Galaxy 3 Series Programming Manual 178 ...
Страница 188: ...Galaxy 3 Series Programming Manual A 4 ...
Страница 202: ...Galaxy 3 Series Programming Manual C 2 ...
Страница 212: ...2 Galaxy 3 Series Programming Manual ...
Страница 213: ...3 Galaxy 3 Series Programming Manual ...