Galaxy 3 Series Programming Manual
92
53 - Program Outputs (cont’d)
Key:
S =
Activates when system is set
? =
Activation dependant on system programming
P
= Activates when system is Part Set
X
= Activates during Exit Time
U
= Unset
E
= Activates during Entry Time
A
= Activated in any condition
L
= Switches output off if linked to destination output
-
= No effect
T
= Activates if zone resistance is less than value for tamper s/c
O
= Activates when zone is omitted
or greater than value for tamper o/c
Table 22C. Output Activations per Zone
Output Functions
Timer-B
Walk
Test
Zone
Omit
Warning
Custom
A
Custom
B
Test
Reset
RQD
Mask
Valid
cd
Fail
Set
Duress
Illegal
Code
Max
Tamp
Abort
Unset
Zone Function
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
01
Final
–
U
O
A
–
–
–
S?
–
–
–
–
–
–
–
–
02
Exit
–
U
O
A
–
–
–
S?
–
–
–
–
–
–
–
–
03
Intruder
–
U
O
A
–
–
–
S?
–
–
–
–
–
–
–
–
04
24 Hours
–
U
O
A
–
–
–
S?
–
–
–
–
–
–
–
–
05
Security
–
U
O
A
–
–
–
S?
–
–
–
–
–
–
–
–
06
Dual
–
U
O
A
–
–
–
S?
–
–
–
–
–
–
–
–
07
Entry
–
U
O
A
–
–
–
S?
–
–
–
–
–
–
–
–
08
Push Set
–
U
O
A
–
–
–
–
–
–
–
–
–
–
–
–
09
Keyswitch
–
U
O
A
–
–
–
–
–
–
UX
–
–
–
–
U
10
Secure Final
–
U
O
A
–
–
–
–
–
–
–
–
–
–
–
–
11
Part Final
–
U
O
A
–
–
–
–
–
–
–
–
–
–
–
–
12
Part Entry
–
U
O
A
–
–
–
–
–
–
–
–
–
–
–
–
13
PA
–
U
O
A
–
–
–
–
–
–
–
–
–
–
–
–
14
PA Silent
–
U
O
A
–
–
–
–
–
–
–
–
–
–
–
–
15
PA Delay
–
U
O
A
–
–
–
–
–
–
–
–
–
–
–
–
16
PA Delay Silent
–
U
O
A
–
–
–
–
–
–
–
–
–
–
–
–
17
Link
?
U?
O?
?
?
?
?
?
?
?
?
?
?
–
?
?
18
Spare
–
–
–
A
–
–
–
–
–
–
–
–
–
?
–
–
19
Fire
–
U
O
A
–
–
–
A?
–
–
–
–
–
–
–
–
20
Tamper
–
U
O
A
–
–
–
A?
–
–
–
–
–
–
–
–
21
Bell Tamper
–
U
O
A
–
–
–
A?
–
–
–
–
–
–
–
–
22
Beam Pair
–
U
O
A
–
–
–
–
–
–
–
–
–
–
–
–
23
Battery Low
–
U
O
A
–
–
–
–
–
–
–
–
–
–
–
–
24
Line Fail
–
U
O
A
–
–
–
–
–
–
–
–
–
–
–
–
25
AC Fail
–
U
O
A
–
–
–
–
–
–
–
–
–
–
–
–
26
Log
–
U
O
A
–
–
–
–
–
–
–
–
–
–
–
–
27
Remote Access
–
U
O
A
–
–
–
–
–
–
–
–
–
–
–
–
28
Video
–
U
O
A
–
–
–
S?
–
–
–
–
–
–
–
–
29
Video Exit
–
U
O
A
–
–
–
S?
–
–
–
–
–
–
–
–
30
Intruder Delay
–
U
O
A
–
–
–
S?
–
–
–
–
–
–
–
–
31
Log Delay
–
U
O
A
–
–
–
–
–
–
–
–
–
–
–
–
32
Set Log
–
U
O
A
–
–
–
–
–
–
–
–
–
–
–
–
33
Custom-A
?
?
O?
?
?
?
?
?
?
?
?
?
?
–
?
?
34
Custom-B
?
?
O?
?
?
?
?
?
?
?
?
?
?
?
?
?
35
Exitguard
L
L
LO
L
L
L
L
L
L
L
L
L
L
?
L
L
36
Mask
–
–
–
–
–
–
–
–
SPE
–
–
–
–
L
?
–
37
Urgent
–
U
O
A
–
–
–
A?
–
–
–
–
–
–
–
–
38
PA Unset
–
U
O
A
–
–
–
U?
–
–
–
–
–
–
–
–
39
Keyswitch Reset
–
U
O
A
–
–
–
–
–
–
–
–
–
–
–
–
40
Bell Fail
–
–
–
A
–
–
–
–
–
–
–
–
–
–
–
–
41
Intr Low
–
U
O
A
–
–
–
S?
–
–
–
–
–
–
–
–
42
Intr High
–
U
O
A
–
–
–
S?
–
–
–
–
–
–
–
–
43
PSU Fault
–
U
O
A
–
–
–
–
–
–
–
–
–
–
–
–
44–46
Not Used
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
47
Vibration
–
U
O
A
–
–
–
A?
–
–
–
–
–
–
–
–
48
ATM-1
–
U
O
A
–
–
–
A?
–
–
–
–
–
–
–
–
49
ATM-2
–
U
O
A
–
–
–
A?
–
–
–
–
–
–
–
–
50
ATM-3
–
U
O
A
–
–
–
A?
–
–
–
–
–
–
–
–
51
ATM-4
–
U
O
A
–
–
–
A?
–
–
–
–
–
–
–
–
52
Alarm Extend
–
U
O
A
–
–
–
A?
–
–
–
–
–
–
–
–
Содержание 3-144
Страница 1: ...Honeywell Security Galaxy 3 48C 3 144 3 144C 3 520 3 520C Programming Manual ...
Страница 2: ......
Страница 8: ...Galaxy 3 Series Programming Manual 2 ...
Страница 30: ...Galaxy 3 Series Programming Manual 24 ...
Страница 184: ...Galaxy 3 Series Programming Manual 178 ...
Страница 188: ...Galaxy 3 Series Programming Manual A 4 ...
Страница 202: ...Galaxy 3 Series Programming Manual C 2 ...
Страница 212: ...2 Galaxy 3 Series Programming Manual ...
Страница 213: ...3 Galaxy 3 Series Programming Manual ...