Galaxy 3 Series Programming Manual
15
Option 12 – Timed Set
This option, when entered, starts the setting routine. The
Entry/Exit Horns
emit the expiry warning using the
programmed exit time (0-300 seconds). The system sets at the end of the exit time or earlier if a
Final Zone
is
opened and closed, key
0
is pressed — if programmed as an exit terminator — or if a push-set terminator is
operated. The option displays the time remaining until the system sets or the number of open zones preventing
the system from setting. Opening a zone during the exit routine resets the exit timer. Pressing the
esc
key prior
to the system setting aborts the setting routine.
NOTE:
The factory default setting allows the timed setting routine to be initiated by entering a valid type2.3
(or above) user code and pressing the
A
key. By default the
A
key is assigned the function Timed
Set. The
A
key can be reprogrammed by the engineer to perform another function, or to start the
setting routine without a code being entered.
Option 13 – Part Set
This option operates exactly as the
Timed Set
option with the exception that only those zones that have the
part attribute enabled (refer to option
52 = PROGRAM ZONES
) are set. All zones have the part attribute
enabled by default. Therefore selecting
PART SET
from the factory will set all zones. The part attribute of
the zones must be disabled if they are not to be included in the part set.
NOTE:
The factory default setting allows the part setting routine to be initiated by entering a valid type 2.3
(or above) user code and pressing the
B
key. By default the
B
key is assigned the function Part Set.
The
B
key can be reprogrammed by the engineer to perform another function, or to start the part
setting routine without a code being entered.
Option 14 – Forced Set (Quick Menu Option 1)
Forced Set
allows a timed set of the system when there are zones that are open at the point of se-
lecting the option
. The open zones must have the omit attribute enabled (refer to option
52 = PROGRAM
ZONES
). This option is only available if the
Forced
parameter (option
51.26
) is enabled; otherwise, the
selection is invalid and the keypad displays the message
Option not available
.
When the
Forced Set
option is entered, the keypad displays the number of zones that have been omitted
(manually by option
11 = OMIT ZONES
and automatically by the
Forced Set
) and the setting routine
begins. If there are any open zones that do not have the omit attribute enabled, the keypad displays the
number of open zones that are not omittable and prompts the user to view them. The non-omittable zones
must be closed before the setting routine can continue.
Option 15 – Chime (Quick Menu Option 2)
The
Chime
option allows the user to switch the chime facility on and off. Any zones that have the chime at-
tribute enabled (refer to option
52 = PROGRAM ZONES
) momentarily operate
Entry/Exit Horns
when
opened; 2 long tones are emitted.
Option 16 – Instant Set
Selecting this option immediately
sets all zones. No sounder or exit time is involved.
NOTE:
The zones must be closed to allow the system to set. If any zones are open, then the exit time reset
feature (detailed previously) is activated.
Options 12 - 16
Содержание 3-144
Страница 1: ...Honeywell Security Galaxy 3 48C 3 144 3 144C 3 520 3 520C Programming Manual ...
Страница 2: ......
Страница 8: ...Galaxy 3 Series Programming Manual 2 ...
Страница 30: ...Galaxy 3 Series Programming Manual 24 ...
Страница 184: ...Galaxy 3 Series Programming Manual 178 ...
Страница 188: ...Galaxy 3 Series Programming Manual A 4 ...
Страница 202: ...Galaxy 3 Series Programming Manual C 2 ...
Страница 212: ...2 Galaxy 3 Series Programming Manual ...
Страница 213: ...3 Galaxy 3 Series Programming Manual ...