ADCSR—A/D Control/Status Register
H'E8
A/D
Bit
Initial value
Read/Write
7
ADF
0
R/(W)
6
ADIE
0
R/W
5
ADST
0
R/W
4
SCAN
0
R/W
3
CKS
0
R/W
0
CH0
0
R/W
2
CH2
0
R/W
1
CH1
0
R/W
*
Note: Only 0 can be written, to clear flag.
*
Channel select 2 to 0
CH2
1
Single Mode
AN
AN
AN
AN
AN
AN
AN
CH1
0
1
0
1
Channel
Selection
CH0
0
1
0
1
0
1
0
1
0
0
1
2
3
4
5
6
AN
7
Scan Mode
AN
AN , AN
AN to AN
AN to AN
AN
AN , AN
AN to AN
0
0
0
0
4
4
4
AN to AN
4
1
5
2
3
6
7
Description
Group
Selection
A/D end flag
A/D interrupt enable
A/D start
Clock select
Scan mode
0
[Clearing condition]
Read ADF while ADF = 1, then write 0 in ADF
1
[Setting conditions]
Single mode:
Scan mode:
0
A/D end interrupt request is disabled
1
A/D end interrupt request is enabled
0
A/D conversion is stopped
1
Single mode:
Scan mode:
0
Single mode
1
Scan mode
0
Conversion time = 266 states (maximum)
1
Conversion time = 134 states (maximum)
A/D conversion ends
A/D conversion ends in all selected channels
A/D conversion starts; ADST is automatically cleared to 0 when
conversion ends
A/D conversion starts and continues, cycling among the selected
channels, until ADST is cleared to 0 by software, by a reset, or by a
transition to standby mode
816