Table 18-23 AC Characteristics in PROM Mode
(Conditions: V
CC
= 5.0 V ± 10%, V
PP
= 12.0 V ± 0.6 V, V
SS
= 0 V, T
a
= 25°C ± 5°C)
Item
Symbol
Min
Typ
Max
Unit
Test Conditions
Command write cycle
t
CWC
120
—
—
ns
Address setup time
t
AS
0
—
—
ns
Address hold time
t
AH
60
—
—
ns
Data setup time
t
DS
50
—
—
ns
Data hold time
t
DH
10
—
—
ns
CE
setup time
t
CES
0
—
—
ns
CE
hold time
t
CEH
0
—
—
ns
V
PP
setup time
t
VPS
100
—
—
ns
V
PP
hold time
t
VPH
100
—
—
ns
WE
programming pulse
t
WEP
70
—
—
ns
width
WE
programming pulse
t
WEH
20
—
—
ns
high time
OE
setup time before
t
OEWS
0
—
—
ns
command write
OE
setup time before verify
t
OERS
6
—
—
µs
Verify access time
t
VA
—
—
500
ns
OE
setup time before status
t
OEPS
120
—
—
ns
polling
Status polling access time
t
SPA
—
—
120
ns
Program wait time
t
PPW
25
—
—
ns
Erase wait time
t
ET
9
—
11
ms
Output disable time
t
DF
0
—
40
ns
Total auto-erase time
t
AET
0.5
—
30
s
Note:
CE
,
OE
, and
WE
should be high during transitions of V
PP
from 5 V to 12 V and from 12 V to
5 V.
*
Input pulse level: 0.45 V to 2.4 V
Input rise time and fall time
≤
10 ns
Timing reference levels: 0.8 V and 2.0 V for input; 0.8 V and 2.0 V for output
Figure 18-25
Figure 18-26
*
Figure 18-27
621