GRA1 H/L—General Register A1 H/L
H'74, H'75
ITU1
GRB1 H/L—General Register B1 H/L
H'76, H'77
ITU1
TCR2—Timer Control Register 2
H'78
ITU2
Bit
Initial value
Read/Write
14
1
R/W
12
1
R/W
10
1
R/W
8
1
R/W
6
1
R/W
0
1
R/W
4
1
R/W
2
1
R/W
15
1
R/W
13
1
R/W
11
1
R/W
9
1
R/W
7
1
R/W
1
1
R/W
5
1
R/W
3
1
R/W
Note: Bit functions are the same as for ITU0.
Bit
Initial value
Read/Write
14
1
R/W
12
1
R/W
10
1
R/W
8
1
R/W
6
1
R/W
0
1
R/W
4
1
R/W
2
1
R/W
15
1
R/W
13
1
R/W
11
1
R/W
9
1
R/W
7
1
R/W
1
1
R/W
5
1
R/W
3
1
R/W
Note: Bit functions are the same as for ITU0.
Bit
Initial value
Read/Write
7
—
1
—
6
CCLR1
0
R/W
5
CCLR0
0
R/W
4
CKEG1
0
R/W
3
CKEG0
0
R/W
0
TPSC0
0
R/W
2
TPSC2
0
R/W
1
TPSC1
0
R/W
Notes:
Bit functions are the same as for ITU0.
When channel 2 is used in phase counting mode, the counter clock source selection by
bits TPSC2 to TPSC0 is ignored.
1.
2.
776