136
―――――――――――――――――――――――――――――――――――――――
11.3 Setting the Trigger Types
―――――――――――――――――――――――――――――――――――
1
2
3
Trigger Screen
Waveform Screen
1
2
3
Method (on the trigger screen and waveform screen)
This example illustrates settings for channel 1.
The
channel 2 is set in the same manner.
Using the
CURSOR
keys, move the flashing cursor in the
order which indicated by the numbers in the figure below,
and set.
1. Set the trigger type:
Using the
+
and
−
keys, select
"
DIP
".
2. Set the frequency:
Using the
+
and
−
keys, set the frequency to
50 Hz or 60 Hz.
3. Set the trigger level:
Using the
+
and
−
keys, set the
trigger level. The rms value is
changed according to the trigger
level.