199
―――――――――――――――――――――――――――――――――――――――
14.6 Troubleshooting
―――――――――――――――――――――――――――――――――――
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
APP
IND
During memory recorder
operation, the apparent
frequency of the recording is
much lower than the
expected frequency.
・
This is likely to be an aliasing error.
・
Make the "time" setting (time axis range)
faster. For more details see the back-
ground information on aliasing distortion in
Appendix "Aliasing".
During operation in the
recorder function mode, the
recording line is very thick.
・
A ripple component in the input signal may
be the cause.
Before the message:
"WARNING 10: Change all
batteries" is displayed, the
printer is stopped.
・
Depending on the battery type and printing
ratio, the printer is stopped before the
message is displayed. Change all new
batteries.
If none of the above conditions apply, and the cause of the
problem is not understood, try performing a system reset.
All the settings will revert to the factory settings.
Also refer to Appendices (Background, Error Message,
Glossary) and Index for more information.
System reset
Method
To perform a system reset, power ON the unit while
holding down the
STOP
key. The settings are initialized,
and revert to the factory settings.
Содержание 8804
Страница 1: ...MEMORY HiCORDER INSTRUCTION MANUAL 8804 ...
Страница 2: ......
Страница 28: ...6 1 2 System Operation ...
Страница 40: ...18 2 1 Main Units Specifications ...
Страница 90: ...68 6 3 Basic Operational Procedures 2 Press the PRINT key The manual print as the figure below is recorded ...
Страница 102: ...80 6 8 Memory Recorder Function Possible Recording Time ...
Страница 128: ...106 8 3 Basic Operational Procedures ...
Страница 200: ...178 12 4 Settings on the System Screen Page 2 ...
Страница 230: ...APPENDIX 8 Appendices Single Dual 2 Recorder function ...
Страница 232: ...APPENDIX 10 Appendices ...
Страница 237: ......
Страница 238: ......